Objective: The study aimed to examine morphometric properties of the round window (RW) and oval window (OW) and to show their relation with the tympanic nerve (the Jacobson's nerve, JN) in human fetuses from the otologic surgeon's perspective.
Methods: Thirty temporal bones of 15 fetal cadavers (8 males, 7 females) aged with 24.40 ± 3.71 weeks were included in the study. The height, width and surface area of the RW and OW and also distance from the JN to the OW and RW were measured.
Results: The height, width and surface area of the RW in this work were measured as 1.48 ± 0.25 mm, 1.57 ± 0.37 mm, and 2.05 ± 0.69 mm, respectively. The RW was detected as round-shaped (8 cases, 26.7%), oval-shaped (15 cases, 50%), and dome-shaped (7 cases, 23.3%). The height, width and surface area of the OW were measured as 1.42 ± 0.26 mm, 2.90 ± 0.44 mm, and 3.63 ± 0.74 mm, respectively. The OW was observed as oval-shaped (15 cases, 50%), kidney-shaped (10 cases, 33.3%), D-shaped (4 cases, 13.3%), and trapezoid-shaped (1 case, 3.3%). The JN was found 1.21 ± 0.60 and 1.18 ± 0.54 mm away from the RW and OW, respectively.
Conclusion: This study containing morphological data about the shapes, diameters and area of the RW and OW may be useful to predict surgical difficulty, and to select implants of suitable size preoperatively for the windows. Knowing the relationship between the JN and the windows can be helpful to avoid iatrogenic injuries of the nerve.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00276-020-02672-8 | DOI Listing |
Int J Pharm
December 2024
Department of Pharmaceutical Engineering, Azrieli College of Engineering Jerusalem, Jerusalem 9103501, Israel. Electronic address:
Chlorhexidine (CHX) is a gold standard therapeutic agent against clinical oral pathogens. However, its oral use is limited due to unpleasant taste, alteration in taste buds, staining of teeth and mucous membranes. Therefore, CHX-loaded PLGA microneedles (MNs) were fabricated for local and controlled release in the oral cavity, using a casting mold method.
View Article and Find Full Text PDFGels
December 2024
Research Institute of Smart Medicine and Biological Engineering, Health Science Center, Ningbo University, Ningbo 315211, China.
Many tissues exhibit structural anisotropy, which imparts orientation-specific properties and functions. However, recapitulating the cellular patterns found in anisotropic tissues presents a remarkable challenge, particularly when using soft and wet hydrogels. Herein, we develop self-assembled anisotropic magnetic FeO micropatterns on polyethylene glycol hydrogels utilizing dipole-dipole interactions.
View Article and Find Full Text PDFNanoscale Adv
December 2024
Department of Electrical and Electronic Engineering, Rajshahi University of Engineering & Technology Rajshahi-6204 Bangladesh
With advancements in photonic technologies, photonic crystal fibers (PCFs) have become crucial components in developing highly sensitive and efficient biosensors. This paper presents an optimized bowtie-shaped PCF biosensor that leverages surface plasmon resonance (SPR) phenomena for enhanced refractive index (RI) sensing. The proposed design uses an external sensing mechanism to effectively characterize performance across an RI range of 1.
View Article and Find Full Text PDFShanghai Kou Qiang Yi Xue
October 2024
Shihezi University School of Medicine; Department of Prosthodontics, Urumqi Stomatological Hospital. Urumqi 830002, Xinjiang Uygur Autonomous Region, China. E-mail:
Purpose: To analyze the effect of n-HA/chitosan/minocycline composite scaffold in the animal model of peri-implant inflammatory bone defect.
Methods: Twelve healthy adult male beagle dogs were selected to construct the model of peri-implant inflammatory bone defect. The control group(n=6) underwent bone regeneration by alveolar self-healing without any treatment in the bone defect area.
Acta Ophthalmol
December 2024
Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate the long-term effects of implantable collamer lens (ICL) V4c on the biomechanical and morphological properties of crystalline lenses in Chinese adults with high myopia using Brillouin microscopy (BM).
Methods: In this case-control study, 102 highly myopic eyes from 102 patients (18-48 years, preoperative spherical equivalent (SE): -6.00--21.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!