Nanotube can be used as a mass sensor. To design a mass sensor for evaluating a high-speed nanoparticle, in this study, we investigated the impact vibration of a cantilever nanobeam being transversally collided by a high-speed C at the beam's free end with an incident velocity of v. The capped beam contains alternately two boron nitride zones and two carbon zones on its cross section. Hence, the relaxed beam has elliptic cross section. The vibration properties were demonstrated by molecular dynamics simulation results. Beat vibration of a slim beam can be found easily. The 1st and the 2nd order natural frequencies (f and f) of the beam illustrate the vibration of beam along the short and the long axes of its elliptic cross section, respectively. f decreases with increasing temperature. A minimal value of v leads to the local buckling of the beam, and a different minimal v leading to damage of the beam. For the same system at a specified temperature, f varies with v. When the beam bends almost uniformly, f decreases linearly with v. If v becomes higher, the beam has a cross section which buckles locally, and the buckling position varies during vibration. If v approaches the damage velocity, a fixed contraflexture point may appear on the beam due to its strong buckling. Above the damage velocity, f decreases sharply. These results have a potential application in design of a mass sensor.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7804857 | PMC |
http://dx.doi.org/10.1038/s41598-020-80202-7 | DOI Listing |
Chem Asian J
January 2025
Chulalongkorn University, Chemistry, THAILAND.
This research focuses on the selective detection of Hg2+ ions using hybrid nanosensors composed of rhodamine building blocks linked to polyamine units of varying chain lengths to produce Rho1-Rho4, which were subsequently conjugated with thioctic acid (RT1-RT4) and attached to the surface of gold nanoparticles to create hybrid nanosensors (GRT1-GRT4) designed for detecting heavy metals. The chemical structures, purity, morphology, and chemical composition were characterized through XRD, NMR, TEM, ATR-FTIR, and mass spectrometry. These hybrid nanosensors demonstrated excellent selectivity and sensitivity in colorimetric and fluorescence responses towards Hg2+, outperforming other metal ions.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Engineering Research Center of Optical Instrument and System, Ministry of Education and Shanghai Key Lab of Modern Optical System, University of Shanghai for Science and Technology, No.516 Jungong Road, Shanghai, 200093, China.
Background: Surface-enhanced Raman scattering (SERS) has attracted much attention as a powerful detection and analysis tool with high sensitivity and fast detection speed. The intensity of the SERS signal mainly depended on the highly enhanced electromagnetic field of nanostructure near the substrate. However, the fabrication of high-quality SERS nanostructured substrates is usually complicated, makes many methods unsuitable for large-scale production of SERS substrates.
View Article and Find Full Text PDFEnviron Res
January 2025
Man-Technology-Environment Research Center (MTM), Örebro University, Örebro SE-701 82, Sweden.
As the volume of plastic waste from electrical and electronic equipment (WEEE) continues to rise, a significant portion is disposed of in the environment, with only a small fraction being recycled. Both disposal and recycling pose unknown health risks that require immediate attention. Existing knowledge of WEEE plastic toxicity is limited and mostly relies on epidemiological data and association studies, with few insights into the underlying toxicity mechanisms.
View Article and Find Full Text PDFSci Total Environ
January 2025
Center for Marine Sensors, Institute for Chemistry and Biology of the Marine Environment (ICBM), Carl von Ossietzky University of Oldenburg, 26382 Wilhelmshaven, Germany.
Microplastics (MP) are known to be ubiquitous. The pathways and fate of these contaminants in the marine environment are receiving increasing attention, but still knowledge gaps exist. In particular, the link between mass-based MP quantification and oceanographic parameters is often lacking.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Faculty of Sports Science, Ningbo University, Ningbo 315211, China.
Barbell squats are commonly used in strength training, but the anterior-posterior displacement of the Center of Mass (COM) may impair joint stability and increase injury risk. This study investigates the key factors influencing COM displacement during different squat modes.; Methods: This study recruited 15 male strength training enthusiasts, who performed 60% of their one-repetition maximum (1RM) in the Front Barbell Squat (FBS), High Bar Back Squat (HBBS), and Low Bar Back Squat (LBBS).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!