A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-Performance Automated Anterior Circulation CT Angiographic Clot Detection in Acute Stroke: A Multireader Comparison. | LitMetric

High-Performance Automated Anterior Circulation CT Angiographic Clot Detection in Acute Stroke: A Multireader Comparison.

Radiology

From the Department of Radiology, New York University Langone Medical Center, 660 First Ave, 2nd Floor, New York, NY 10016 (S.D.); Department of Neurology, Stanford University Hospital, Stanford, Calif (M.L., C.V., J.H.); Department of Neurology, Ente Ospedaliero Cantonale, Lugano, Switzerland (C.C.); Departments of Neurology (F.L., H.C., F.R.) and Radiology (F.M.), Hospital Geral de Fortaleza, Fortaleza, Brazil; Department of Neurology, Kansas University Medical Center, Kansas City, Kan (A.Q.); LifeBridge, Baltimore, Md (H.H.); and Boulder Statistics, Boulder, Colo (K.C.).

Published: March 2021

Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and data complexity compel the development of fast, reliable, and automated tools for LVO detection to facilitate acute imaging triage. Purpose To investigate the performance of an anterior circulation LVO detection platform in a large mixed sample of individuals with and without LVO at cerebrovascular CT angiography (CTA). Materials and Methods In this retrospective analysis, CTA data from recent cerebrovascular trials (CRISP [ NCT01622517] and DASH) were enriched with local repositories from 11 worldwide sites to balance demographic and technical variables in LVO-positive and LVO-negative examinations. CTA findings were reviewed independently by two neuroradiologists from different institutions for intracranial internal carotid artery (ICA) or middle cerebral artery (MCA) M1 LVO; these observers were blinded to all clinical variables and outcomes. An automated analysis platform was developed and tested for prediction of LVO presence and location relative to reader consensus. Discordance between readers with respect to LVO presence or location was adjudicated by a blinded tertiary reader at a third institution. Sensitivity, specificity, and receiver operating characteristics were assessed by an independent statistician, and subgroup analyses were conducted. Prespecified performance thresholds were set at a lower bound of the 95% CI of sensitivity and specificity of 0.8 or greater at mean times to notification of less than 3.5 minutes. Results A total of 217 study participants (mean age, 64 years ± 16 [standard deviation]; 116 men; 109 with positive findings of LVO) were evaluated. Prespecified performance thresholds were exceeded (sensitivity, 105 of 109 [96%; 95% CI: 91, 99]; specificity, 106 of 108 [98%; 95% CI: 94, 100]). Sensitivity and specificity estimates across age, sex, location, and vendor subgroups exceeded 90%. The area under the receiver operating characteristic curve was 99% (95% CI: 97, 100). Mean processing and notification time was 3 minutes 18 seconds. Conclusion The results confirm the feasibility of fast automated high-performance detection of intracranial internal carotid artery and middle cerebral artery M1 occlusions. © RSNA, 2021 See also the editorial by Kloska in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2021202734DOI Listing

Publication Analysis

Top Keywords

sensitivity specificity
12
anterior circulation
8
lvo
8
lvo detection
8
intracranial internal
8
internal carotid
8
carotid artery
8
middle cerebral
8
cerebral artery
8
lvo presence
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!