Addition of Screening Breast US to Digital Mammography and Digital Breast Tomosynthesis for Breast Cancer Screening in Women at Average Risk.

Radiology

From the Department of Radiology, Seoul National University Hospital Healthcare System Gangnam Center, 101 Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea (A.Y., B.R.K.); Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Republic of Korea (M.J.J., D.Y.); Department of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul, Republic of Korea (S.U.S.); and Department of Radiology, Seoul National University College of Medicine and Seoul National University Hospital, Seoul, Republic of Korea (J.M.C.).

Published: March 2021

Background Digital breast tomosynthesis (DBT) with or without digital mammography (DM) is the primary method of breast cancer screening. However, the sufficiency of DBT screening for women at average risk and the need for supplemental whole-breast US needs further investigation. Purpose To evaluate the added value of supplemental US screening following combined DM/DBT. Materials and Methods A retrospective database search identified consecutive asymptomatic women who underwent DM/DBT and radiologist-performed screening breast US simultaneously between March 2016 and December 2018. The cancer detection rate (CDR) per 1000 screening examinations, sensitivity, specificity, and abnormal interpretation rate of DM/DBT and DM/DBT combined with US were compared. Results A total of 1003 women (mean age, 56 years ± 8.6 [standard deviation]) were included. Among them, 12 cancers (mean invasive tumor size, 14 mm; range, 6-33 mm) were diagnosed. With DM/DBT and DM/DBT combined with US, the CDRs were 9.0 per 1000 screening examinations (nine of 1003 women; 95% CI: 4.1, 17) and 12 per 1000 screening examinations (12 of 1003 women; 95% CI: 6.2, 21), respectively, and the abnormal interpretation rates were 7.8% (78 of 1003 women; 95% CI: 6.2, 9.6) and 24% (243 of 1003 women; 95% CI: 22, 27). In women with negative findings at DM/DBT, supplementary US yielded a CDR of 3.2 per 1000 examinations (three of 925 women; 95% CI: 0.7, 9.4), sensitivity of 100% (three of three women; 95% CI: 29, 100), specificity of 82% (760 of 922 women; 95% CI: 80, 85), and abnormal interpretation rate of 18% (165 of 925 women; 95% CI: 15, 21). The three additional US-detected cancers were identified in women with dense breasts; no benefit was observed in women with nondense breasts. Conclusion The addition of breast US to digital mammography and digital breast tomosynthesis yielded an additional 0.7-9.4 cancers per 1000 women at average risk, with a substantial increase in the abnormal interpretation rate. © RSNA, 2021 See also the editorial by Rahbar in this issue.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2021203134DOI Listing

Publication Analysis

Top Keywords

women 95%
32
1003 women
20
women
16
abnormal interpretation
16
digital mammography
12
digital breast
12
breast tomosynthesis
12
women average
12
average risk
12
1000 screening
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!