The objective of this systematic review was to evaluate the stability and complications of tooth-borne (TB), bone-borne (BB) and hybrid (TB-BB) appliances in surgically assisted rapid maxillary expansion (SARME). Database searches were conducted (PubMed, Embase, Cochrane Library and SciELO), as well as a grey literature search (Google Scholar) and hand searches of reference lists. Forty-six articles were included after study selection (κ=0.854). After eligibility assessment, 16 articles and one article from the grey literature were processed (κ=0.866) and six articles were selected by hand searching, for a total of 23 articles included. Regarding stability, TB appliances showed width relapse rates ranging from 4 to 35% in canines, from 1 to 37% in premolars and from 0.2 to 49.5% in molars. In BB appliances, width relapse rates were 1.7-21% in canines, 1.5% in premolars and 4.6-11.5% in molars. In hybrid appliances, the width relapse rate was 14% in premolars, with a 1.8% overexpansion reported in the molar region. In TB and BB appliances, skeletal relapse rates were similar on the nasal floor (11-53% and 41.6%, respectively) and at the level of the maxilla (18% and 16%, respectively). The most common complications were bone resorption in TB appliances (18.14%) and appliance-related complications in BB appliances (17.9%). The risk of bias was high in 19 studies, medium in three studies and low in one study. The TB and BB appliances used in SARME were considered to have a high long-term stability. BB appliances appeared to have fewer relapses than TB appliances due to a more parallel distribution of forces exerted. However, relapse appears to be highly influenced by postorthodontic treatments, where arch-form coordination is achieved in the consolidation period with the purpose of overexpansion correction, alignment and final vertical adjustments. Further randomised controlled trials with long-term data and large sample sizes are needed to support evidence-based clinical decision-making and to allow meta-analytic studies of stability outcomes regarding the type of anchorage in SARME.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjoms.2020.08.017DOI Listing

Publication Analysis

Top Keywords

appliances width
12
width relapse
12
relapse rates
12
appliances
11
complications tooth-borne
8
tooth-borne bone-borne
8
assisted rapid
8
rapid maxillary
8
maxillary expansion
8
systematic review
8

Similar Publications

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

A localized surface plasmon resonance (LSPR) sensor based on tapered optical fiber (TOF) using hollow gold nanoparticles (HAuNPs) for measuring the refractive index (RI) is presented. This optical fiber sensor is a good candidate for a label-free RI biosensor. In practical biosensors, bioreceptors are immobilized on nanoparticles (NPs) that only absorb specific biomolecules.

View Article and Find Full Text PDF

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.

View Article and Find Full Text PDF

Postoperative pseudomeningocele is a rare, but still existing, complication after spinal surgeries. It may be asymptomatic or presented with back pain, radicular pain or headaches. Many pseudomeningoceles resolve spontaneously, others require revision surgery with dural repair.

View Article and Find Full Text PDF

Effect of post-processing on the surface, optical, mechanical, and dimensional properties of 3D-printed orthodontic clear retainers.

Clin Oral Investig

January 2025

School of Materials Science and Innovation, Faculty of Science, Mahidol University, Phuttamonthon 4 Road, Salaya, Phuttamonthon District, Nakhon Pathom, 73170, Thailand.

Objectives: To address the high surface roughness and poor optical properties of three-dimensional (3D) printed orthodontic clear retainers, an alternative post-processing protocol was investigated with the goal of achieving improved surface, optical, and mechanical properties while preserving dimensional accuracy.

Materials And Methods: Samples were prepared from two biocompatible methacrylate-based 3D-printing resins (Formlabs Dental LT Clear V2, NextDent OrthoFlex) and one thermoplastic material (Duran). For the 3D-printed resins, one group was post-processed by rinsing in isopropyl alcohol, while another group was centrifuged before post-curing in glycerine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!