Ultrasound (US) guided medical devices placement is a widely used clinical technology, yet many factors affect the visualization of these devices in the human body. In this research, an ultrasound-activated film was developed that can be coated on the surface of medical devices. The film contains 2 μm silica microshells and poly(methyl 2-cyanoacrylate) (PMCA) adhesive. The air sealed in the hollow space of the microshells acted as the US contrast agent. Ozone and perfluorooctyltriethoxysilane (PFO) were used to treat the surface of the film to enhance the US signals and provide durable antifouling properties for multiple passes through tissue, consistent with the dual oleophobic and hydrophobic nature of PFO. In vitro and in vivo tests showed that hypodermic needles and tumor marking wires coated with US activated film gave strong and persistent color Doppler signals. This technology can significantly improve the visibility of medical devices and the accuracy of US guided medical device placement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsbiomaterials.7b00223 | DOI Listing |
Biomed Phys Eng Express
January 2025
Shandong University of Traditional Chinese Medicine, Qingdao Academy of Chinese Medical Sciences, Jinan, Shandong, 250355, CHINA.
Mild cognitive impairment (MCI) is a significant predictor of the early progression of Alzheimer's disease, and it can be used as an important indicator of disease progression. However, many existing methods focus mainly on the image itself when processing brain imaging data, ignoring other non-imaging data (e.g.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
Department of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125.
Cognition relies on transforming sensory inputs into a generalizable understanding of the world. Mirror neurons have been proposed to underlie this process, mapping visual representations of others' actions and sensations onto neurons that mediate our own, providing a conduit for understanding. However, this theory has limitations.
View Article and Find Full Text PDFOtol Neurotol
February 2025
Department of Otorhinolaryngology-Head and Neck Surgery, Donders Center for Neuroscience, Radboud University Medical Center, Radboud University, Nijmegen, the Netherlands.
Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs).
Study Design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP.
Setting: Tertiary referral center.
Otol Neurotol
February 2025
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.
Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).
Study Design: Retrospective cohort study.
Setting: Tertiary academic medical center.
Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.
Study Design: Prospective performance study.
Setting: Secondary care.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!