A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel device prototyping for endoscopic cell sheet transplantation using a three-dimensional printed simulator. | LitMetric

Novel device prototyping for endoscopic cell sheet transplantation using a three-dimensional printed simulator.

Regen Ther

Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto, 606-8507, Japan.

Published: December 2020

Introduction: Considering higher risks of candidates for cardiac regenerative therapy with compromised cardiac function, it is anticipated to develop less invasive surgical procedures. In the present study, we aimed to develop a prototype of totally endoscopic cell sheet delivery device and evaluate the surgical technique for epicardial cell sheet placement using three-dimensional (3D) printed simulators based on human computed tomography data.

Methods: We designed an endoscopic cell sheet delivery device with outer and inner frame with self-expandable applicator which can be opened in thoracic cavity. We launched spout line to provide liquids on the applicator surface and tension line to gently bend the applicator dorsally. We prepared human mesenchymal stem cell (MSC) sheets and compared wet/dry conditions of 3D printed heart/porcine heart and applicator to identify suitable conditions for cell sheet transplantation. Finally we validated the feasibility of endoscopic transplantation to anterior and lateral wall of left ventricle using 3D printed simulators.

Results: Moist condition of both 3D printed heart/porcine heart surface and applicator at transplantation yielded highest successful rate (100%, p = 0.0197). For both endoscopic transplantation sites, MSC sheets were successfully deployed. The procedure duration was 157 ± 23 s for anterior wall and 123 ± 13 s for the lateral wall in average, respectively.

Conclusions: We developed a novel prototype of endoscopic cell sheet delivery device for minimally-invasive cardiac regenerative therapy utilizing a 3D printed simulator. The commercialization of the prototype may provide a safe minimally-invasive method to deliver potential cardiac regenerative therapy in the future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7770426PMC
http://dx.doi.org/10.1016/j.reth.2020.10.007DOI Listing

Publication Analysis

Top Keywords

cell sheet
24
endoscopic cell
16
cardiac regenerative
12
regenerative therapy
12
sheet delivery
12
delivery device
12
sheet transplantation
8
three-dimensional printed
8
printed simulator
8
msc sheets
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!