Purpose: Central retinal vein occlusion (CRVO) entails retinal hypoxia that often causes visual impairment. It has been shown that oxygen saturation in larger retinal vessels correlates with the visual acuity at the time of diagnosis of CRVO but has no predictive value for the visual outcome in patients treated with anti-VEGF medication after 3 months. However, assessing the predictive value of retinal oxygen saturation after 12 months is essential because this is when the main restitution after CRVO occurs.

Methods: Retinal oximetry was performed in 117 patients referred with CRVO to three European centres. The correlation between oxygen saturation and visual acuity at baseline and the predictive value of oxygen saturation in larger retinal vessels for the 12-month visual outcome after treatment with anti-VEGF medication were studied.

Results: In the affected eye, the oxygen saturation was significantly higher in the arterioles, significantly lower in the venules, and the arterio-venous (A-V) significantly higher than in the unaffected eye (p < 0.001 for all comparisons). Correlations between best-corrected visual acuity (BCVA) and oxygen saturations were moderate and negative for arterioles (p < 0.001), positive for venules (p = 0.03) and negative for the A-V difference (p = 0.001). Best-corrected visual acuity (BCVA), but not oxygen saturation or the other explanatory variables at baseline, contributed significantly to predicting BCVA after 12 months.

Conclusion: Retinal vessel oxygen saturation is affected in CRVO, and saturation correlates with BCVA. However, retinal oximetry cannot replace measures of visual function as a predictor of visual outcome after 12 months of anti-VEGF treatment for CRVO.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aos.14744DOI Listing

Publication Analysis

Top Keywords

oxygen saturation
20
visual outcome
12
retinal
8
retinal oximetry
8
12-month visual
8
central retinal
8
retinal vein
8
vein occlusion
8
saturation larger
8
larger retinal
8

Similar Publications

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.

View Article and Find Full Text PDF

The effect of skin pigmentation on photoplethysmography and, specifically, pulse oximetry has recently received a significant amount of attention amongst researchers, especially since the COVID-19 pandemic. With most computational studies observing overestimation of arterial oxygen saturation (SpO) in individuals with darker skin, this study seeks to further investigate the root causes of these discrepancies. This study analysed intensity changes from Monte Carlo-simulated reflectance PPG signals across light, moderate, and dark skin types at oxygen saturations of 70% and 100% in MATLAB R2024a.

View Article and Find Full Text PDF

Perioperative cardiac arrest (POCA) remains a major challenge in surgical settings, with low survival after cardiopulmonary resuscitation (CPR). This study aims to identify predictive factors for 24 h survival after CPR and cause of POCA. A retrospective, single-center study was conducted on patients aged ≥18 years who experienced POCA and received CPR in the operating room or within 2 h postoperatively at Chiang Mai University Hospital from 2010 to 2019.

View Article and Find Full Text PDF

The autologous reconstruction of the female breast using a microsurgical DIEP flap is a reliable and safe method. To detect impairments early and preserve the microvascular flap through timely revision, a better understanding of physiologic perfusion dynamics is necessary. This exploratory study examines changes in microcirculation in free DIEP flaps within the first 72 h after vascular anastomosis using laser Doppler flowmetry and white-light spectrophotometry.

View Article and Find Full Text PDF

Something Old and Something New-A Pilot Study of Shrinkage and Modern Imaging Devices.

Life (Basel)

December 2024

Department of Plastic and Hand Surgery and Laboratory for Tissue Engineering and Regenerative Medicine, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany.

Shrinkage, a heat-induced process, reorganizes collagen fibers, thereby reducing wound surface area. This technique, commonly applied in surgeries like periareolar mastopexy and skin grafting, is well-established. Despite its widespread use, modern imaging has recently enabled detailed observation of shrinkage's effects on tissue temperature and oxygenation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!