Multiple number of techniques and devices have been described concerning circumcision method so far. One of them is thermocautery device, and it has been widely used. Although there is controversy that the penis may be damaged due to the heat generated during the use of the device, not enough histopathological studies have been conducted. We aimed to determine the histopathological changes in human foreskin caused by heat after circumcision with thermocautery and to demonstrate the safety of the use of a thermocautery-assisted circumcision. Forty-one patients were divided into two groups according to the thermal energy used during cutting with thermocautery as follows: high temperature (Group 1, n = 22) and low temperature (Group 2, n = 19). The effect of the heat intensity and depth of the coagulation necrosis produced with thermocautery-assisted circumcisions performed at low and high temperatures were evaluated. The difference between the groups was not statistically significant. Tissue damage is extremely limited in thermocautery-assisted circumcisions, even when it is used at high temperatures. The thermocautery device can be used for effective and safe circumcisions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/and.13968 | DOI Listing |
Lasers Surg Med
December 2024
Center for Cancer Immunology and Cutaneous Biology Research Center, Department of Dermatology and Center for Cancer Research, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Objective: Physical treatment modalities, such as ablative fractional laser (AFL), electrocautery, and cryotherapy, are extensively used in the field of dermatology. This study aimed to characterize the short-term innate and adaptive immune responses induced by AFL compared with heat- and cold-based procedures.
Materials And Methods: Innate (CD11bLy6G neutrophils) and adaptive (CD8CD3 T cells) immune cell infiltration and histopathological changes were examined in murine skin on Days 1 and 7, following AFL, monopolar-electrocautery (RF), thermocautery, and cryotherapy.
Int J Mol Sci
March 2023
Department of Ophthalmology, Baylor College of Medicine, Houston, TX 77030, USA.
Conjunctivochalasis is a degenerative condition of the conjunctiva that disrupts tear distribution and causes irritation. Thermoreduction of the redundant conjunctiva is required if symptoms are not relieved with medical therapy. Near-infrared laser treatment is a more controlled method to shrink the conjunctiva than thermocautery.
View Article and Find Full Text PDFOphthalmic Plast Reconstr Surg
March 2023
Department of Ophthalmology and Visual Sciences, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, U.S.A.
Purpose: Implantable electronic cardiovascular device such as cardiac pacemakers and implantable defibrillators are common life-saving devices. Device-related complications can arise when undergoing surgical interventions with electrosurgical tools due to electromagnetic interference, based on electrocautery type, implantable electronic cardiovascular device type, electrocautery location, and a number of other factors. The risk of device-related complications due to electrocautery in oculoplastic surgery has not been established.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
September 2022
Dry Eye and Cornea Treatment Center Tampa, Florida, 33609, USA.
Purpose: To report the successful approach to managing neuropathic dry eye-like pain (NP) in three consecutive patients described as severe: 1) "burning fire," "burning acid," and "horrible burning pain" with hyperalgesia and allodynia, 2) refractory to topical anesthetic (TA), and 3) without surface hyperemia nor vital staining.
Observations: Two of three patients' pain was reversed with significant symptom relief within 48 hours by identification of occult obstructive Meibomian gland dysfunction (o-MGD) and treatment using Meibomian gland probing (MGP) with intraductal steroid lavage (MGP) and aqueous tear deficiency (ATD) treated with punctal thermocautery (PO). The third patient's pain was reversed within one week after treatment of superior conjunctivochalasis (CCh) using amniotic membrane surface reconstruction and ATD using PO with subsequent MGP and MGP for o-MGD.
Arq Bras Oftalmol
May 2023
Cataract Department, Santa Casa de Misericórdia de Belo Horizonte, Belo Horizonte, MG, Brazil.
Purpose: To evaluate the stability and efficacy of the double-flanged 5-0 polypropylene suture to fixate subluxated cataracts at 18 months and the possible complications of this new technique.
Methods: This technique uses a 5-0 polypropylene monofilament to create two flanges with a thermocautery, for fixation of a capsular tension segment to the sclera to fix the subluxated capsular bag. This technique was implemented in 17 eyes requiring intraocular lens implantation in a setting of zonular dialysis due to trauma, Marfan syndrome, microspherophakia, idiopathic disease, and post-phacoemulsification status.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!