The efficient removal of toxic metals ions from chemical industry wastewater is considered problematic due to the existence of pollutants as mixtures in the aqueous matrix, thus development of advanced and effective treatment method has been identified as a panacea to the lingering problems of heavy metal pollution. In this study, KIAgNPs decorated MWCNTs nano adsorbent was developed using combination of green chemistry protocol and chemical vapor deposition techniques and subsequently characterized using UV-Vis, HRTEM, HRSEM, XRD, FTIR and XPS. The adsorptive efficiency of MWCNTs-KIAgNPs for the removal of Cr(VI), Ni(II), Fe(II), Cd(II) and physico-chemical parameters like pH, TDS, COD, BOD, nitrates, sulphates, chlorides and phosphates from chemical industrial wastewater was examined in both batch and fixed bed systems. The result exhibited successful deposition of KIAgNPs on the surface of MWCNTs as confirmed by the microstructures, morphology, crystalline nature, functional groups and elemental characteristics of the MWCNTs-KIAgNPs. Optimum batch adsorption parameters include; pH (3 for Cr(VI) and 6 for Ni(II), Fe(II) and Cd(II) ions), contact time (60 min), adsorbent dosage (40 mg) and temperature (318 K). The binding capacities were obtained as follows; Cr (229.540 mg/g), Ni (174.784 mg/g), Fe (149.552) and Cd (121.026 mg/g), respectively. Langmuir isotherm and pseudo-second order kinetic model best described the experimental data in batch adsorption, while the thermodynamic parameters validated the chemisorption and endothermic nature of the adsorption process. In continuous adsorption, the metal ions were effectively removed at low metal influent concentration, low flow rate and high bed depth, whereby the experimental data were designated by Thomas model. The high physico-chemical parameters in the wastewater were successfully treated in both batch and fixed bed systems to fall within WHO permissible concentrations. The adsorption/desorption study illustrated over 80% metal removal by MWCNTs-KIAgNPs even after 8th adsorption cycle. This study demonstrated excellent performance of MWCNTs-KIAgNPs for chemical industry wastewater treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7794394PMC
http://dx.doi.org/10.1038/s41598-020-79857-zDOI Listing

Publication Analysis

Top Keywords

crvi niii
12
niii feii
12
feii cdii
12
batch fixed
12
fixed bed
12
cdii ions
8
kiagnps decorated
8
decorated mwcnts
8
chemical industry
8
industry wastewater
8

Similar Publications

Article Synopsis
  • - The study introduces Bacillus enclensis AGM_Cr8, a marine bacterium found in polluted Versova Creek, Mumbai, that displays significant tolerance to chromate stress and other heavy metals such as lead and arsenic.
  • - Various microscopic techniques show how AGM_Cr8 absorbs chromate, with evidence of both surface interaction and internal bioaccumulation, suggesting a bioreduction mechanism that converts harmful Cr(VI) into less toxic Cr(III).
  • - Genome sequencing reveals twenty-two genes related to chromate tolerance and detoxification processes, indicating AGM_Cr8's potential for bioremediation of chromium contamination in the environment.
View Article and Find Full Text PDF

Sorption of metal ions onto PET-derived microplastic fibres.

Environ Sci Process Impacts

December 2024

School of Chemistry and Chemical Engineering, University of Surrey, Guildford, Surrey GU2 7XH, UK.

Article Synopsis
  • This study explored how microplastic polyester fibers, specifically polyethylene terephthalate (PET), can absorb various metal ions found in sewage.
  • The research found that PET fibers could effectively retain metal ions like lead, cadmium, and mercury, with lead showing the highest absorption capacity.
  • The findings suggest that when these microplastics are present in sewage treatment, they can contribute to the transfer of hazardous metals into the environment, particularly when sewage sludge is used on agricultural land.
View Article and Find Full Text PDF

Mechanochemical Thioglycolate Modification of Microscale Zero-Valent Iron for Superior Heavy Metal Removal.

Angew Chem Int Ed Engl

January 2025

Key Laboratory of Pesticide & Chemical Biology of Ministry of Education, Institute of Applied & Environmental Chemistry, College of Chemistry, Central China Normal University, Wuhan, 430079, P. R. China.

Microscale zero-valent iron (mZVI) is widely used for water pollutant control and environmental remediation, yet its reactivity is still constrained by the inert oxide shell. Herein, we demonstrate that mechanochemical thioglycolate (TG) modification can dramatically enhance heavy metal (Ni, Cr, Cd, Pb, Hg, and Sb) removal rates of mZVI by times of 16.7 to 88.

View Article and Find Full Text PDF

Heavy metal contamination is an increasing global threat to human and environmental health, particularly in resource-limited areas. Traditional platforms for heavy metal detection are labor intensive and expensive and require lab facilities. While paper-based colorimetric sensors offer a simpler approach, their sensitivity limitations prevent them from meeting legislative requirements for many metals.

View Article and Find Full Text PDF

Efficient chromium(VI) removal using trioctylmethylammonium salicylate as the carrier in polymer inclusion membranes.

Environ Sci Pollut Res Int

August 2024

Laboratoire de Physique Et Chimie Des Matériaux (LPCM), Université Mouloud Mammeri, Route de Hasnaoua, 15000, Tizi-Ouzou, Algeria.

Article Synopsis
  • - The study focused on creating a polymer inclusion membrane (PIM) using the ionic liquid TOMAS incorporated into cellulose triacetate (CTA) to effectively remove chromium (Cr(VI)) from solutions.
  • - The optimal PIM composition was found to be a 50% mixture of CTA and TOMAS without any plasticizers, allowing transport of Cr(VI) from a solution at pH 2 to a receiving solution of NaOH, achieving a selective recovery rate of 93.61% even in the presence of other metals.
  • - Although the membrane maintained high efficiency for 5 days of use, there was a slight decrease in its performance over time, indicating the need to evaluate long-term stability for practical applications
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!