A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Operational Modal Analysis, Testing and Modelling of Prefabricated Steel Modules with Different LSF Composite Walls. | LitMetric

The modal properties of modular structures, such as their natural frequencies, damping ratios and mode shapes, are different than those of conventional structures, mainly due to different structural systems being used for assembling prefabricated modular units onsite. To study the dynamic characteristics of modular systems and define a dynamic model, both the modal properties of the individual units and their connections need to be considered. This study is focused on the former aspect. A full-scale prefabricated volumetric steel module was experimentally tested using operational modal analysis technique under pure ambient vibrations and randomly generated artificial hammer impacts. It was tested in different situations: [a] bare (frame only) condition, and [b] infilled condition with different configurations of gypsum and cement-boards light-steel framed composite walls. The coupled module-wall system was instrumented with sensitive accelerometers, and its pure and free vibration responses were synchronously recorded through a data acquisition system. The main dynamic characteristics of the module were extracted using output-only algorithms, and the effects of the presence of infill wall panels and their material are discussed. Then, the module's numerical micromodel for bare and infilled states is generated and calibrated against experimental results. Finally, an equivalent linear strut macro-model is proposed based on the calibrated data. The contribution of this study is assessing the effects of different infill wall materials on the dynamic characteristics of modular steel units, and proposing simple models for macro-analysis of infilled module assemblies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767127PMC
http://dx.doi.org/10.3390/ma13245816DOI Listing

Publication Analysis

Top Keywords

dynamic characteristics
12
operational modal
8
modal analysis
8
composite walls
8
modal properties
8
characteristics modular
8
infill wall
8
analysis testing
4
testing modelling
4
modelling prefabricated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!