Recent years have seen the dynamic development of methods for functionalizing the surface of implants using biomaterials that can mimic the physical and mechanical nature of native tissue, prevent the formation of bacterial biofilm, promote osteoconduction, and have the ability to sustain cell proliferation. One of the concepts for achieving this goal, which is presented in this work, is to functionalize the surface of NiTi shape memory alloy by an atypical glass-like nanocomposite that consists of SiO-TiO with silver nanoparticles. However, determining the potential medical uses of bio(nano)coating prepared in this way requires an analysis of its surface roughness, tribology, or wettability, especially in the context of the commonly used reference coat-forming hydroxyapatite (HAp). According to our results, the surface roughness ranged between (112 ± 3) nm (Ag-SiO)-(141 ± 5) nm (HAp), the water contact angle was in the range (74.8 ± 1.6)° (Ag-SiO)-(70.6 ± 1.2)° (HAp), while the surface free energy was in the range of 45.4 mJ/m (Ag-SiO)-46.8 mJ/m (HAp). The adhesive force and friction coefficient were determined to be 1.04 (Ag-SiO)-1.14 (HAp) and 0.247 ± 0.012 (Ag-SiO) and 0.397 ± 0.034 (HAp), respectively. The chemical data showed that the release of the metal, mainly Ni from the covered NiTi substrate or Ag from Ag-SiO coating had a negligible effect. It was revealed that the NiTi alloy that was coated with Ag-SiO did not favor the formation of or biofilm compared to the HAp-coated alloy. Moreover, both approaches to surface functionalization indicated good viability of the normal human dermal fibroblast and osteoblast cells and confirmed the high osteoconductive features of the biomaterial. The similarities of both types of coat-forming materials indicate an excellent potential of the silver-silica composite as a new material for the functionalization of the surface of a biomaterial and the development of a new type of functionalized implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7825542PMC
http://dx.doi.org/10.3390/ijms22020507DOI Listing

Publication Analysis

Top Keywords

niti shape
8
shape memory
8
memory alloy
8
surface roughness
8
hap surface
8
surface
7
hap
6
key properties
4
properties bioactive
4
bioactive ag-sio/tio
4

Similar Publications

This retrospective study evaluates the clinical impact of perioperative multimodal analgesia in the minimally invasive treatment of severe blunt chest trauma with hemopneumothorax using a thoracoscopic Ni-Ti shape memory embracing plate. A total of 100 patients with severe blunt chest trauma and moderate to severe hemopneumothorax treated at Hanyang Hospital affiliated with Wuhan University of Science and Technology from January 2019 to January 2022 were enrolled. Patients were divided into 2 groups: a control group (50 patients) receiving patient-controlled intravenous analgesia (PCIA), and a study group (50 patients) administered a multimodal analgesia regimen.

View Article and Find Full Text PDF

Comparison of mechanical properties and shaping performance of ProGlider and ProTaper ultimate slider.

BMC Oral Health

January 2025

Department of Conservative Dentistry, College of Dentistry, Kyung Hee University, 26-6, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02453, Republic of Korea.

Background: This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved artificial canal.

Methods: Scanning electron microscopy, micro-computed tomography, and differential scanning calorimetry were used to characterize the samples. A torsional resistance test was performed to obtain ultimate strength and distortion angle.

View Article and Find Full Text PDF

Quality of Machined Surface and Cutting Force When Milling NiTi Alloys.

Materials (Basel)

December 2024

Faculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Krakow, Poland.

The machining of shape memory alloys, such as NiTi, presents challenges due to their specific physical, chemical, and mechanical properties. This study investigated the effect of the helix angle of milling tools-both uncoated and coated-on the cutting forces and the surface roughness of the milling process for a NiTi alloy. Experiments were conducted using the tools with and without coatings at various helix angles (20°, 30°, and 40°) and under different machining conditions.

View Article and Find Full Text PDF

The preservation of the original configurations of root canals during endodontic preparation is crucial for treatment success. Nickel-titanium (NiTi) rotary systems have been refined to optimize canal shaping while minimizing iatrogenic errors. This study aimed to evaluate and compare the shaping efficacy of the novel R-Motion (RM) and the established WaveOne Gold (WG) systems using micro-computed tomography (micro-CT).

View Article and Find Full Text PDF

Background: The fracture of an endodontic instrument within the root canal system can occur during root canal therapy, complicating thorough cleaning and shaping. Consequently, managing the broken fragment becomes crucial.

Methods: Eighty Nickel-titanium (NiTi) #20 K-files (Mani, Tochigi, Japan) were cut 8 mm from the tip, fixed into a corkboard, and classified into five groups (n = 14 each).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?