A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Near-field sensor array with 65-GHz CMOS oscillators for rapid detection of viable Escherichia coli. | LitMetric

Near-field sensor array with 65-GHz CMOS oscillators for rapid detection of viable Escherichia coli.

Biosens Bioelectron

Sharp Fukuyama Semiconductor Co., Ltd, Tenri, Nara, 632-8567, Japan. Electronic address:

Published: March 2021

In this study, the growth of Escherichia coli was monitored using a complementary metal-oxide-semiconductor (CMOS) near-field sensor array. Each of the 1488 integrated elements, arranged in a 3 mm square, has a resonator that oscillates at 65 GHz. The effective capacitance of the resonator is altered by changes in the dielectric properties of the sensor surface, which shifts the resonance frequency. Growth curves of E. coli at different initial concentrations (OD = 0.01, 0.03, and 0.05) were monitored. A suspension with initial turbidity of OD = 0.05 was cultured in a medium, and the sensor successfully distinguished between viable E. coli and heat-treated dead E. coli in 20 min. Moreover, the apparent suppression of growth was observed in the presence of 500 μg/mL streptomycin. As the sensor is composed of arrayed elements, and the area of sensitivity distribution of the element is larger than the size of one bacteria, the variation in the output value of each element may reflect the number and movement of bacteria. This study revealed that the presence of viable E. coli could be rapidly confirmed by using the change in permittivity caused by the displacement of media by E. coli near the sensor surface.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2020.112935DOI Listing

Publication Analysis

Top Keywords

near-field sensor
8
sensor array
8
escherichia coli
8
sensor surface
8
viable coli
8
coli
7
sensor
5
array 65-ghz
4
65-ghz cmos
4
cmos oscillators
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!