Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study aimed to assess and compare the systemic response of oxygen uptake kinetics and muscle deoxygenation between a 30-min rest protocol and a multivisit protocol on the parameters of the power-duration relationship (i.e., critical power [CP] and W').
Methods: Nine endurance-trained triathletes reported to the laboratory on five occasions: a preliminary graded exercise test and a familiarization, a 30-min single-visit protocol (time trials of 10, 5, and 2 min in that order interspersed with 30 min rest), and a multivisit protocol (time trials of 10, 5, and 2 min in randomized order interspersed by >24 h rest). Heart rate (HR) was recorded continuously, respiratory gases were measured breath by breath, and deoxygenation was recorded at 10 Hz using near-infrared spectroscopy (NIRS) during all tests. Blood lactate (BLa-) concentration was measured before all time trials. Maximal HR (HRmax), oxygen uptake (V˙O2) during the first 2 min (V˙O2onset), mean response time, end-exercise V˙O2 (V˙O2peak), V˙O2 amplitude (amplV˙O2), O2 deficit, NIRS τ, amplitude (amplNIRS), and time delay were assessed. To compare the two protocols and to assess the differences in W' and CP, a paired sample t-test was used as well as a two-way ANOVA to assess the differences between trials and/or protocols, including trial-protocol interactions.
Results: No significant differences, and trivial effect sizes, were found for W' and CP between protocols (P = 0.106-0.114, d < 0.01-0.08). Furthermore, no significant differences between protocols were found for all parameters, except for [BLa-]. Significant differences between trials were found for V˙O2ampl, V˙O2onset, NIRS τ, amplNIRS, [BLa-], and HRmax.
Conclusion: Results suggest that W' and CP can be determined using the 30-min rest protocol without confounding effects of previous severe exercise compared with the multivisit protocol.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1249/MSS.0000000000002477 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!