A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of position and exercise on measurement of muscle quantity and quality: towards a standardised pragmatic protocol for clinical practice. | LitMetric

Background: Ultrasonography is an emerging non-invasive bedside tool for muscle quantity/quality assessment; Bioelectrical Impedance Analysis (BIA) is an alternative non-invasive bedside measure of body composition, recommended for evaluation of sarcopenia in clinical practice. We set out to assess impact of position and exercise upon measures towards protocol standardisation.

Methods: Healthy volunteers aged 18-35 were recruited. Bilateral Anterior Thigh Thickness (BATT; rectus femoris and vastus intermedius), BATT: Subcutaneous Ratio (BATT:SCR), and rectus femoris echogenicity were measured using ultrasound and BIA was performed; 1) lying with upper body at 45° (Reclined), 2) lying fully supine at 180 (Supine), 3) sat in a chair with upper body at 90 (Sitting), and 4) after exercise Reclined. Variability of Skeletal Muscle Mass (SMM) by two different equations from BIA (SMM-Janssen, SMM-Sergi), phase angle, fat percentage, and total body (TBW), extracellular (ECW), and intracellular water (ICW) were assessed.

Results: Forty-four participants (52% female; mean 25.7 years-old (SD 5.0)) were recruited. BATT increased from Reclined to Sitting (+ 1.45 cm, 1.27-1.63), and after exercise (+ 0.51, 0.29-0.73). Echogenicity reduced from Reclined to Sitting (- 2.1, - 3.9 - -0.26). SMM-Sergi declined from Reclined to Supine (- 0.65 kg, - 1.08 - - 0.23) and after exercise (- 0.70 kg, - 1.27 - -0.14). ECW increased from Reclined to Sitting (+ 1.19 L, 0.04-2.35). There were no other statistically significant changes.

Conclusion: Standardisation of protocols is especially important for assessment of muscle quantity by ultrasonography; BIA measurements may also vary dependent on the equations used. Where possible, participants should be rested prior to muscle ultrasonography and BIA, and flexion of the knees should be avoided.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7792326PMC
http://dx.doi.org/10.1186/s13102-020-00227-3DOI Listing

Publication Analysis

Top Keywords

reclined sitting
12
position exercise
8
muscle quantity
8
clinical practice
8
non-invasive bedside
8
rectus femoris
8
upper body
8
increased reclined
8
ultrasonography bia
8
reclined
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!