Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct.

Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure.

Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( = .029).

Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9608281PMC
http://dx.doi.org/10.1177/1558944720974111DOI Listing

Publication Analysis

Top Keywords

headless compression
20
load failure
16
compression screw
12
single- double-screw
12
scaphoid nonunions
8
dual-screw fixation
8
compression screws
8
screws scaphoid
8
nonunion model
8
construct stiffness
8

Similar Publications

Retrograde intramedullary headless compression screw fixation for pediatric mid-diaphyseal proximal phalanx malunion: A case study.

Int J Surg Case Rep

January 2025

Department of Orthopaedics and Traumatology, AZ Delta, Deltalaan 1, 8800 Roeselare, Belgium; Department of Cardio and Organ Systems, Hasselt University, Martelarenlaan 42, 3500 Hasselt, Belgium. Electronic address:

Introduction: Proximal phalanx fractures in children, especially mid-diaphyseal fractures, can result in malunion and significant functional impairment. Early malunions require prompt and effective intervention to prevent long-term complications. This case study highlights the use of intramedullary headless compression screw (IMHCS) fixation in addressing a proximal phalanx malunion.

View Article and Find Full Text PDF

Minimally Invasive Placement of Cannulated Headless Compression Screws for Reduction of Sacroiliac Luxation in 14 Cats.

Vet Comp Orthop Traumatol

December 2024

Surgery Department, Evidensia Dierenziekenhuis Hart van Brabant, Waalwijk, Brabant, The Netherlands.

Objective:  To describe percutaneous fluoroscopy-guided placement of self-drilling, self-tapping, 3.0 mm cannulated headless compression screws (HCS) for surgical reduction of sacroiliac luxation (SIL) in cats, and to document clinical outcome.

Materials And Methods:  Medical records of cats with SIL, managed by percutaneous fluoroscopy-guided placement of a 3.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of two types of bone grafts (packed cancellous vs. corticocancellous) used in repairing scaphoid waist nonunion fractures with volar locking plates.
  • Postoperative CT scans showed that 95% of patients achieved osseous bridging, but those with packed cancellous grafts had significantly better healing outcomes than those with corticocancellous grafts.
  • The findings suggest that using packed cancellous autografts may lead to faster and more effective bone healing in these cases.
View Article and Find Full Text PDF

Purpose: The Evidence-Based Practice Committee of the American Society for Surgery of the Hand set out to assess the membership's practice patterns (PPs) and familiarity with evidence-based principles for scaphoid fracture and nonunion management.

Methods: Using a consensus-generated 25-item online survey, all the American Society for Surgery of the Hand members were invited to participate via email in September 2023. Two question types were used including evidence-based practice (EBP) and PPs.

View Article and Find Full Text PDF

 To describe the procedure and evaluate the results of a series of patients with stable and unstable pseudarthrosis of the scaphoids treated with the use of arthroscopy associated with cancellous bone graft and compression screw.  Twenty-three patients were treated with this technique. The minimum postoperative follow-up was 12 months, and pre- and postoperative functional, clinical, and imaging analyses were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!