A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cas12a-based electrochemiluminescence biosensor for target amplification-free DNA detection. | LitMetric

Cas12a-based electrochemiluminescence biosensor for target amplification-free DNA detection.

Biosens Bioelectron

School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang, 212013, China. Electronic address:

Published: March 2021

CRISPR/Cas system have drawn increasing attention in accurate and sensitive nucleic acids detection. Herein, we reported a novel Cas12a-based electrochemiluminescence biosensor for target amplification-free human papilloma virus subtype (HPV-16) DNA detection. During this detection process, Cas12a employed its two-part recognition mechanism to improve the specificity and trans-cleavage capability to achieve signal amplification, while L-Methionine stabilized gold nanoclusters (Met-AuNCs) were served as high-efficiency ECL emitters to achieve ECL signal transition. Given the unique combination of Cas12a with ECL technique, the detection limit was determined as 0.48 pM and the whole detection could be completed within 70 min. We also validated the practical application of the proposed biosensor by using undiluted human blood samples, which gives impetus to the design of new generations of CRISPR/Cas detection system beyond the traditional ones with ultimate applications in sensing analysis and diagnostic technologies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2020.112954DOI Listing

Publication Analysis

Top Keywords

cas12a-based electrochemiluminescence
8
electrochemiluminescence biosensor
8
biosensor target
8
target amplification-free
8
dna detection
8
detection
7
amplification-free dna
4
detection crispr/cas
4
crispr/cas system
4
system drawn
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!