Aims: (1) To present the design of a novel intravaginal dynamometer (IVD) capable of measuring vaginal closure force on both the anterior and posterior arms, (2) to use bench testing to validate the force, speed of arm opening, and positional accuracy of load measurement along the IVD arms, and (3) to present in vivo force measurements made with this device, comparing forces measured by the anterior and posterior arms.
Methods: IVD load measurements were validated against an Instron® Universal Tester, arm opening speeds were validated using video analysis, and position-load accuracy was validated against calibration weights. In vivo IVD data were acquired from female volunteers during passive opening and pelvic floor muscle contraction tasks. Anterior and posterior IVD arm force outcomes were compared.
Results: Forces measured by the IVD and Instron® exhibited a strong linear relationship with excellent model fit. The speed control system was valid when tested under physiological loading conditions, however smaller antero-posterior opening diameters (25 and 30 mm) exhibited some error. The loading position along the IVD arms had no effect on force outcomes. In vivo data exhibited differences between force outcomes measured at the anterior and posterior aspects of the vagina during active contraction and passive elongation of the pelvic floor muscles.
Conclusions: This IVD design demonstrates valid load measurement and speed control during bench testing. Active and passive forces measured are consistent with the literature. With dual instrumented arms, this device allows for further investigation into the source of measured vaginal closure forces.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nau.24600 | DOI Listing |
Turk Kardiyol Dern Ars
January 2025
Department of Cardiology, Isfahan University of Medical Sciences, Isfahan, Iran.
Hypereosinophilic syndrome (HES) is traditionally described as chronic peripheral eosinophilia with involvement of various organs and systems, including the heart and nervous system. In this report, we describe cardiac involvement and border zone stroke in a patient with idiopathic HES. A 37-year-old woman presented with sudden right-sided weakness and slurred speech, which began four days before admission, accompanied by palpitations, retrosternal exertional chest discomfort, dry cough, and progressive shortness of breath over approximately two months.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Istanbul 34093, Turkey.
This study aimed to determine the relationship between alpha angle (the angle between the screws and the glenoid) and thoracic diameters in patients undergoing the Latarjet procedure. Defining the relationship between thoracic morphology and alpha angle is aimed at filling the gap in the literature and improving surgical outcomes. This retrospective study analyzed 74 patients who underwent the Latarjet procedure for recurrent anterior shoulder instability between 2022 and 2024.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Ophthalmology, St. Barbara Hospital, Trauma Centre, 41-200 Sosnowiec, Poland.
The aim of this retrospective study was to compare corneal parameters and compliance using a Pentacam HR-Scheimpflug (Pentacam HR) and a swept-source OCT Casia (Casia) in keratoconus (KC) patients post penetrating keratoplasty (PKP) and KC patients without PKP, as well as a control group. Pachymetry measurements were also analyzed using a spectral domain OCT Solix (OCT Solix), Pentacam HR, and Casia. The study included 71 patients (136 keratoconic eyes; group A), 86 eyes with KC post-PKP (group B), 50 eyes with KC without PKP (group C), and 52 control participants (104 eyes).
View Article and Find Full Text PDFJ Clin Med
December 2024
"Joint-Stock Company" Central Clinical Hospital, Almaty 050060, Kazakhstan.
Intracranial atherosclerosis (ICAS) is a major cause of ischemic stroke, disproportionately affecting populations with significant vascular risk factors. Although ICAS imposes a considerable health burden, research on this condition in Central Asia remains scarce, especially among the Kazakh population. This study analyzes demographic characteristics, treatment outcomes, and procedural challenges associated with ICAS in 216 patients treated at a single institution.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Unidad de Investigación en Fisioterapia, Spin off Centro Clínico OMT-E Fisioterapia SLP, Universidad de Zaragoza, Domingo Miral s/n, 50009 Zaragoza, Spain.
The anatomy of the pelvis may obscure differences in pelvic tilt, potentially underestimating its correlation with clinical measures. Measuring the total sagittal range of pelvic movement can serve as a reliable indicator of pelvic function. This study assessed the inter- and intra-examiner reliability of the Kinovea version 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!