A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Highly Selective Turn-on Fluorescent and Naked-eye Colourimetric Dual-channel Probe for Cyanide Anions Detection in Water Samples. | LitMetric

A highly selective turn-on fluorescent and naked-eye colourimetric dual-channel probe for cyanide anions (CN-) has been designed and characterized. In the mixed solution (DMSO / HO, 9:1, v / v), only CN- could cause an increase in the UV absorption intensity and the corresponding fluorescence intensity increased, and other anions had no significant effect on the probe. After treatment with cyanide in the probe solution, the solution showed a noticeable colour change, from light yellow to purple. Moreover, a fluorescence spectrophotometer can be used to observe that the fluorescence intensity of the solution is significantly enhanced. The response of the colourimetric and fluorescent dual-channel probe to CN- was attributed to nucleophilic addition, and the mechanism was determined by H NMR spectroscopy. In addition, this probe was used to detect CN- in actual water samples, including river water, drinking water, and tap water. The spiked CN- recovery rate is very high (97.2%-100.06%), and analytical precision is also very high (RSD < 2%), which shows its feasibility and reliability for detecting cyanide ions in actual water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10895-020-02677-xDOI Listing

Publication Analysis

Top Keywords

dual-channel probe
12
highly selective
8
selective turn-on
8
turn-on fluorescent
8
fluorescent naked-eye
8
naked-eye colourimetric
8
colourimetric dual-channel
8
probe cyanide
8
cyanide anions
8
water samples
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!