Herein, a facile and low-cost method for the preparation of activated carbon from peanut shell was developed for the first time for the fast extraction and determination of Bisphenol A in human urine. Bisphenol A was separated by EC-C18 column (250 mm×4.6 mm, 4 μm) and was detected by VWD, with retention time for qualitative analysis and peak area for quantitation. The parameters, pH values of the urine, adsorbent dose, adsorption time and so on, were optimized to achieve the excellent extraction performance. The detection limit of Bisphenol A in human urine was 1.0 ng · mL (S/N = 3), and the standard curve was linear in the range of 5.0 ng · mL˜200.0 ng · mL ( = 0.9993). The average recovery of Bisphenol A was 78.5˜96.2% at three spiked levels in the range of 5.00 ng · mL˜200.00 ng·mL. The method was proved simple, practical and highly sensitive, which could satisfy the request for the determination of Bisphenol A in human urine.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2021.18980DOI Listing

Publication Analysis

Top Keywords

bisphenol human
16
human urine
16
determination bisphenol
12
preparation activated
8
activated carbon
8
carbon peanut
8
peanut shell
8
bisphenol
6
urine
5
facile preparation
4

Similar Publications

Bisphenols may negatively impact human health. In this study, we propose the use of HPLC-FLD for the simultaneous determination of bisphenols in pericardial fluid samples collected from patients with coronary artery disease undergoing coronary artery bypass surgery. For sample preparation, a fast, simple, and "green" DLLME method was used, achieving mean recovery values in the range of 62%-98% with relative standard deviations between 2% and 6% for all analytes.

View Article and Find Full Text PDF

Bisphenol S induced endothelial dysfunction via mitochondrial pathway in the vascular endothelial cells, and detoxification effect of albumin binding.

Chem Biol Interact

January 2025

College of Chemistry and Materials, Key Laboratory of Green Catalysis of Jiangxi Education Institutes, Jiangxi Normal University, Nanchang, 330022, China. Electronic address:

As a replacement of bisphenol A, bisphenol S (BPS) is commonly used in the wrappers and food containers of daily life. Epidemiological studies demonstrate a close link between BPS exposure and vascular diseases, where the biological activities of BPS remain scarcely known. Herein, the effects of BPS on endothelial function as well as the underlying mechanism were investigated in human umbilical vein endothelial cells (HUVECs) and mouse arteries.

View Article and Find Full Text PDF

Safer chemical alternatives to bisphenol (BP) have been a major pursuit of modern green chemistry and toxicology. Using a chemical similarity-based approach, it is difficult to identify minor structural differences that contribute to the significant changes of toxicity. Here, we used omics and computational toxicology to identify chemical features associated with BP analogue-induced embryonic toxicity, offering valuable insights to inform the design of safer chemical alternatives.

View Article and Find Full Text PDF

Covalent Organic Framework Nanofilm-Assisted Laser Desorption Ionization Mass Spectrometry for Rapid Screening of Parabens in Personal Care Products.

Rapid Commun Mass Spectrom

April 2025

State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong SAR, China.

Rational: People are widely exposed to parabens in their daily life, but parabens are endocrine disrupting chemicals that pose a threat to human health. Therefore, establishing a rapid screening method to enhance monitoring of parabens is necessary. Herein, a covalent organic framework (COF) nanofilm-assisted laser desorption ionization mass spectrometry (LDI-MS) method was established to screen parabens in personal care products (PCPs).

View Article and Find Full Text PDF

4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis.

Anal Chim Acta

January 2025

Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:

Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!