To examine new evidence linking expanded hemodialysis (HDx) using a medium cut-off (MCO) membrane with hospitalizations, hospital days, medication use, costs, and patient utility. This retrospective study utilized data from Renal Care Services medical records database in Colombia from 2017 to 2019. Clinics included had switched all patients from high flux hemodialysis (HD HF) to HDx and had at least a year of data on HD HF and HDx. Data included demographic characteristics, comorbidities, years on dialysis, hospitalizations, medication use, and quality of life measured by the 36 item and Short Form versions of the Kidney Disease Quality of Life survey at the start of HDx, and 1 year after HDx, which were mapped to EQ-5D utilities. Generalized linear models were run on the outcomes of interest with an indicator for being on HDx. Annual cost estimates were also constructed. The study included 81 patients. HDx was significantly associated with lower dosing of erythropoietin stimulating agents, iron, hypertension medications, and insulin. HDx was also significantly associated with lower hospital days per year (5.94 on HD vs. 4.41 on HDx) although not with the number of hospitalizations. Estimates of annual hospitalization costs were 23.9% lower using HDx and patient utilities did not appear to decline. HDx was statistically significantly associated with reduced hospitalization days and lower medication dosages. Furthermore, this preliminary analysis suggested potential for HDx being a dominant strategy in terms of costs and utility and should motivate future work with larger samples and better controls.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451823 | PMC |
http://dx.doi.org/10.1111/1744-9987.13620 | DOI Listing |
Protein Sci
January 2025
Department of Physics, University of Toronto, Toronto, Ontario, Canada.
The point mutation N642H of the signal transducer and activator of transcription 5B (STAT5B) protein is associated with aggressive and drug-resistant forms of leukemia. This mutation is thought to promote cancer due to hyperactivation of STAT5B caused by increased stability of the active, parallel dimer state. However, the molecular mechanism leading to this stabilization is not well understood as there is currently no structure of the parallel dimer.
View Article and Find Full Text PDFProtein Sci
January 2025
Department of Chemistry, Columbia University, New York, New York, USA.
The rapid identification of protein-protein interactions has been significantly enabled by mass spectrometry (MS) proteomics-based methods, including affinity purification-MS, crosslinking-MS, and proximity-labeling proteomics. While these methods can reveal networks of interacting proteins, they cannot reveal how specific protein-protein interactions alter protein function or cell signaling. For instance, when two proteins interact, there can be emergent signaling processes driven purely by the individual activities of those proteins being co-localized.
View Article and Find Full Text PDFProteins
December 2024
Institute of Protein Research, Russian Academy of Sciences, Pushchino, Russia.
Hydrogen-deuterium exchange mass spectrometry (HDX-MS) approach has become a valuable analytical complement to traditional methods. HDX-MS allows the identification of dynamic surfaces in proteins. We have shown that the introduction of various mutations into the amino acid sequence of whale apomyoglobin (apoMb) leads to a change in the number of exchangeable hydrogen atoms, which is associated with a change in its compactness in the native-like condition.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
December 2024
Institute for Bioscience and Biotechnology Research, National Institute of Standards and Technology and the University of Maryland, College Park, Rockville, Maryland 20850, United States.
Sample carryover is a common problem in hydrogen-deuterium exchange mass spectrometry, particularly because immobilized protease columns cannot withstand the high organic solvent concentrations typically used in liquid chromatography-mass spectrometry (LC-MS) for cleaning. Conventional cleaning methods using injections of guanidine HCl still suffer from carryover and may require four blanks after each sample run to fully remove carryover. We have implemented an additional LC pump to deliver customized wash solutions to protease and enzyme columns, and the associated LC capillaries to eliminate carryover.
View Article and Find Full Text PDFJ Mass Spectrom
January 2025
Department of Chemical Engineering and Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, Eindhoven, The Netherlands.
One critical issue in hydrogen/deuterium exchange mass spectrometry (HDX MS) analysis is the deleterious back exchange. Herein, we report that when matrix-assisted laser desorption/ionization (MALDI) is used, the MALDI process itself can also cause significant back exchange. The back exchange occurred inside the reactive MALDI plume was investigated by depositing a fully deuterated sample prepared in DO on top of a preloaded dried layer of matrix.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!