Analyser-based phase-contrast imaging (ABPCI) is a highly sensitive phase-contrast imaging method that produces high-contrast images of weakly absorbing materials. However, it is only sensitive to phase gradient components lying in the diffraction plane of the analyser crystal [i.e. in one dimension (1-D)]. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase-sensitive methods must achieve 2-D phase gradient sensitivity. An inclined geometry method was applied to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase-sensitive phase-contrast method to possess 2-D phase gradient sensitivity. Tomographic datasets were acquired over 360° of a multi-material phantom with the detector and sample tilted by 8°. The real and imaginary parts of the refractive index were reconstructed for the phantom.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S1600577520013995 | DOI Listing |
Trials
January 2025
Université Côte d'Azur, CNRS, LP2M, Nice, France.
Background: /aims. Pseudoxanthoma Elasticum (PXE, OMIM 264800) is an autosomal, recessive, metabolic disorder characterized by progressive ectopic calcification in the skin, the vasculature and Bruch's membrane. Variants in the ABCC6 gene are associated with low plasma pyrophosphate (PPi) concentration.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
GE Healthcare, Guangzhou 510623, China.
Background: Accurate preoperative prediction of vascular invasion in breast cancer is crucial for surgical planning and patient management. MRI radiomics has shown promise in enhancing diagnostic precision. This study aims to evaluate the effectiveness of integrating MRI radiomic features with clinical data using a deep learning approach to predict vascular invasion in breast cancer patients.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
STZ eyetrial at the Centre for Ophthalmology, Tuebingen, Germany.
Purpose: Reports of gene therapy-associated retinal atrophies and inflammation have highlighted the importance of preclinical safety assessments of adeno-associated virus (AAV) vector systems. We evaluated in nonhuman primates (NHPs) the ocular safety and toxicology of a novel AAV gene therapy targeting retinitis pigmentosa caused by mutations in PDE6A, which has since been used in a phase I/II clinical trial (NCT04611503).
Methods: A total of 34 healthy cynomolgus animals (Macaca fascicularis) were treated with subretinal injections of rAAV.
J Clin Gastroenterol
January 2025
The Third Central Hospital of Tianjin, Hedong District.
Goals: To explore dynamic contrast-enhanced ultrasound (CEUS) parameters in predicting hepatic vein pressure gradient (HVPG) for patients with liver cirrhosis (LC).
Background: Noninvasive diagnosis of HVPG remains a challenge.
Study: This prospective study included patients with LC undergoing hepatic vein catheterization and pressure measurement at the hospital from May 2021 to January 2023.
HardwareX
March 2025
LIGHT Community, Physics Department, Imperial College London SW7 2AZ, UK.
We recently demonstrated polarisation differential phase contrast microscopy () as a robust, low-cost single-shot implementation of (semi)quantitative phase imaging based on differential phase microscopy. utilises a polarisation-sensitive camera to simultaneously acquire four obliquely transilluminated images from which phase images mapping spatial variation of optical path difference can be calculated. microscopy can be implemented on existing or bespoke microscopes and can utilise radiation at a wide range of visible to near infrared wavelengths and so is straightforward to integrate with fluorescence microscopy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!