On the Weldability of Thick P355NL1 Pressure Vessel Steel Plates Using Laser Welding.

Materials (Basel)

Department of Laser Material Processing, RAPTECH s.r.o., U Vodárny 473, 330 08 Zruč-Senec, Czech Republic.

Published: December 2020

Pipeline transport uses millions of kilometers of pipes worldwide to transport liquid or gas over long distances to the point of consumption. High demands are placed, especially on the transport of hazardous substances under high pressure (gas, oil, etc.). Mostly seamless steel pipes of various diameters are used, but their production is expensive. The use of laser-welded pipes could significantly reduce the cost of building new pipelines. However, sufficient mechanical properties need to be ensured for welded pipes to meet stringent requirements. Therefore, laser-welded 10 mm thick pressure vessel steel plates were subjected to various mechanical tests, including high-cycle fatigue tests. Furthermore, the microstructural parameters and the state of residual stresses were determined using X-ray and neutron diffraction, which could affect fatigue life, too. The critical areas for possible crack initialization, especially in and near the heat-affected zone, were found using different tests. The presented results outline the promising application potential of laser welding for the production of pipes for high-pressure pipelines.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795705PMC
http://dx.doi.org/10.3390/ma14010131DOI Listing

Publication Analysis

Top Keywords

pressure vessel
8
vessel steel
8
steel plates
8
laser welding
8
pipes
5
weldability thick
4
thick p355nl1
4
p355nl1 pressure
4
plates laser
4
welding pipeline
4

Similar Publications

: Vascular aging is associated with increased arterial stiffness and changes in the wall structure, leading to a loss of elasticity. Silicon is abundant in arteries and plays a key role in the synthesis and stabilization of elastin fibers. In animal models of accelerated cardiovascular aging, a specific nutritional supplement based on silicon-enriched spirulina (SpSi) has been shown to have beneficial effects on vascular function.

View Article and Find Full Text PDF

Angiotensin II (Ang II)-induced hypertension increases afferent (AA) and efferent (EA) arteriole resistances via the actions of Ang II on the AT1 receptor. In addition to the increased interstitial levels of Ang II, the increased arterial pressure increases interstitial ATP concentrations. In turn, ATP acts on the purinergic receptors P2X1 and P2X7 to constrict the AA, preventing increases in plasma flow and single-nephron GFR (SNGFR).

View Article and Find Full Text PDF

Meningeal Lymphatic and Glymphatic Structures in a Pelagic Delphinid ().

Animals (Basel)

March 2025

Department of Biology and Marine Biology, College of Science and Engineering, University of North Carolina Wilmington, Wilmington, NC 28403, USA.

The glymphatic system, an analog of the peripheral lymphatic system in the brain, and the meningeal lymphatic system are critical to central nervous system health. The glymphatic system functions to distribute cerebrospinal fluid and important compounds throughout the brain and to remove metabolic waste. The flow of cerebrospinal fluid through this system is affected by changes in cerebral blood flow, intracranial pressure, and vascular tone.

View Article and Find Full Text PDF

Purpose: To compare automated and semiautomated methods for the measurement of retinal microvascular biomarkers: the automated retinal vascular morphology (AutoMorph) algorithm and the Singapore "I" Vessel Assessment (SIVA) software.

Methods: Analysis of retinal fundus photographs centered on optic discs from the population-based Montrachet Study of adults aged 75 years and older. Comparison and agreement evaluation with intraclass correlation coefficients (ICCs) between SIVA and AutoMorph measures of the central retinal venular and arteriolar equivalent, arteriolar-venular ratio, and fractal dimension.

View Article and Find Full Text PDF

Association of abdominal aortic calcification with cognitive impairment in peritoneal dialysis patients.

BMC Nephrol

March 2025

Department of Nephrology, Beijing Luhe Hospital, Capital Medical University, NO.82 Xinhua South Road, Tongzhou District, Beijing, 101100, China.

Background: Patients on peritoneal dialysis (PD) frequently have cognitive impairment, which is linked to a poor prognosis. The purpose of this study was to determine whether abdominal aortic calcification (AAC) may have an impact on PD patients' cognitive function.

Methods: In this cross-sectional study of 110 PD patients, cognitive function was assessed using the Montreal Cognitive Assessment (MoCA), and AAC severity was quantified via lateral lumbar radiography (Kauppila method).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!