Skin tests for the detection of Mycobacterial infections: achievements, current perspectives, and implications for other diseases.

Appl Microbiol Biotechnol

HDT Bio Corp, 1616 Eastlake Ave E, Seattle, WA, 98102, USA.

Published: January 2021

Immunological and molecular advances have modernized diagnostic testing for many diseases. Although interferon gamma-release and polymerase chain reaction assays have been developed to detect Mycobacterium tuberculosis (Mtb) infection, purified protein derivative (PPD)-based tuberculin skin testing (TST) remains the most widely used method. Indeed, the TST is a simple and cost-effective tool that can be easily applied for widespread screening for Mtb infection. However, the lack of specificity has been a limitation of these tests, and, more recently, supply issues have arisen. Building upon the skin tests that historically have been used within TB and leprosy control programs, we discuss recent developments using modern technologies for improving mycobacterial skin testing as well as practical advantages inherent to the technique. Furthermore, we outline how this knowledge could be applied to develop similar tests that could benefit diagnostic strategies for other infections. KEY POINTS: • Skin testing provides a significantly cheaper alternative to most modern technologies. • Skin tests provide a lab-independent diagnostic strategy that can be widely administered. • Diseases for which T cell responses are more robust or durable than antibody responses are accessible for skin testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7780083PMC
http://dx.doi.org/10.1007/s00253-020-11062-4DOI Listing

Publication Analysis

Top Keywords

skin testing
16
skin tests
12
mtb infection
8
modern technologies
8
• skin
8
skin
7
testing
5
tests detection
4
detection mycobacterial
4
mycobacterial infections
4

Similar Publications

Self-rerouting sensor network for electronic skin resilient to severe damage.

Nat Commun

January 2025

Toyota Central R&D Labs. Inc.; 41-1, Yokomichi, Nagakute, Aichi, Japan.

We propose a network architecture for electronic skin with an extensive sensor array-crucial for enabling robots to perceive their environment and interact effectively with humans. Fault tolerance is essential for electronic skins on robot exteriors. Although self-healing electronic skins targeting minor damages are studied using material-based approaches, substantial damages such as severe cuts necessitate re-establishing communication pathways, traditionally performed with high-functionality microprocessor sensor nodes.

View Article and Find Full Text PDF

Octyl succinic anhydride-modified chitosan/oxidized sodium alginate Schiff base hydrogel loaded with terbinafine hydrochloride: pH-responsive, self-repairing, antifungal properties.

Int J Biol Macromol

January 2025

Guangxi Key Laboratory of Animal Breeding, Disease Control and Prevention, College of Animal Science and Technology, Guangxi University, Nanning, Guangxi 530004, China; Guangxi Zhuang Autonomous Region Engineering Research Center of Veterinary Biologics, Nanning, Guangxi 530004, China. Electronic address:

The application of hydrogels to drug delivery limited by the difficulty of encapsulating hydrophobic drugs; therefore, the development of novel composite hydrogels for the delivery of hydrophobic drugs is urgently needed. In this study, terbinafine hydrochloride/hydroxypropyl-β-cyclodextrin inclusion complexes (TFH/HP-β-CD ICs) were added to a Schiff base hydrogel matrix containing octenyl succinic anhydride-modified chitosan (OSA-CS) and sodium alginate (OIA) to prepare a TFH composite hydrogel (TFH GEL). The results revealed that the solubility of TFH in water within TFH/HP-β-CD IC reached 32.

View Article and Find Full Text PDF

Pre-established anaesthetic protocols in animal models might unexpectedly interfere with the main outcome of scientific projects and therefore they need to account for the specific research goals. We aimed to optimize the anaesthetic protocol and animal handling strategies in a diabetes-related-study exemplifying how the anaesthetic approach must be adjusted for individual research targets. Aachen minipigs were used as a model to test long-lasting skin glucose sensors for diabetic human patients.

View Article and Find Full Text PDF

Background: Understanding the median nerve's position relative to surrounding anatomy is essential; however, there are many variations among individuals. This study assesses differences in median nerve position with or without palmaris longus (PL). We hypothesize that PL presence alters median nerve position, resulting in a greater distance to the skin volar surface, a decreased distance to the radius volar surface, and an increased distance to the flexor carpi radialis (FCR).

View Article and Find Full Text PDF

Background: Glecaprevir/pibrentasvir is an effective antiviral therapy for hepatitis C virus infection and is generally regarded safe in patients with renal impairment. However, renal complications are a notable, albeit rare, concern.

Case Presentation: We report a case of acute kidney injury in a man in his 50s with chronic hepatitis C virus, chronic obstructive pulmonary disease, morbid obesity, a history of heroin dependence, and untreated type 2 diabetes mellitus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!