Purpose The aim of this study is to investigate the feasibility of prostate stereotactic body radiation therapy treatment with a newly developed Varian Halcyon 2.0 machine by comparing radiotherapy plans with previously delivered CyberKnife G4 plans created with the previous version of CyberKnife Treatment Planning System Multiplan 4.6.1. Methods Fifteen previously treated prostate stereotactic body radiation therapy treatment CyberKnife plans were re-planned retrospectively according to the Radiation Therapy Oncology Group 0938 protocol on a Halcyon 2.0 machine with a prescription of 3625 cGy in five fractions. Results All re-plans on a Halcyon 2.0 were able to meet the Radiation Therapy Oncology Group 0938 protocol goals and constraints. The re-plans decreased the maximum dose to skin and urethra, mean doses to the bladder and rectum, and also improve the conformity index and the Planning Target Volume coverage. However, D1cc to the rectum, D1cc and D10% to the bladder increased with no statistically significant differences (p > 0.05) with the re-plans. Conclusion The Halcyon 2.0 can generate stereotactic body radiation therapy treatment prostate plans created based on the Radiation Therapy Oncology Group 0938 protocol by delivering adequate coverage to the target while sparing healthy tissues.