Stanmore total hip replacement. A nine- to ten-year follow-up.

J Bone Joint Surg Br

R. K. Hospital, Groningen, The Netherlands.

Published: January 1988

Between February 1975 and August 1976, 195 total hip replacements using Stanmore components were performed; of these, 146 were in 135 patients who had not had previous hip surgery. At review 52 had died, but none of the others was lost to follow-up. Of the 52, two had had a second operation, one for infection and one for recurrent dislocation. In the remaining 83 patients (92 hips) five revisions were necessary: four for aseptic loosening, and one for stem fracture. The remaining 78 patients had little or no pain and little restriction of activity. After a follow-up period of at least nine years, the survival rate of the prosthesis was 95%. There had been migration of the femoral component in five cases and migration of the acetabular cup in one case, but no wear of the acetabular component could be demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.70B1.3339059DOI Listing

Publication Analysis

Top Keywords

total hip
8
remaining patients
8
stanmore total
4
hip replacement
4
replacement nine-
4
nine- ten-year
4
ten-year follow-up
4
follow-up february
4
february 1975
4
1975 august
4

Similar Publications

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Theoretically, animals with longer hindlimbs are better jumpers, while those with shorter hindlimbs are better maneuverers. Yet experimental evidence of this relationship in mammals is lacking. We compared jump force and maneuverability in a lab population of Mongolian gerbils (Meriones unguiculatus).

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Purpose Low-dose total skin electron beam therapy (LD-TSEBT) has recently gained popularity in treating mycosis fungoides (MF) due to its reduced toxicity and favorable response rates. Combining accelerated LD-TSEBT with the modified Stanford technique (mST), a condensed cycling approach, offers a promising and convenient option. However, in vivo dosimetry data confirming the effectiveness of this approach is limited.

View Article and Find Full Text PDF

Introduction: Hip fractures are common and are a major cause of significant morbidity and mortality in the elderly population, particularly when treatment is delayed. The British Orthopaedic Association's (BOA) guidelines state that surgical treatment should be performed within 36 hours of admission. This study aimed to investigate the effects of delays in surgery on clinical outcomes and to evaluate mortality rates over a three-year follow-up period following proximal femoral fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!