Purpose: To determine the impact of mechanical stability on the progress of bone ongrowth on the frame surfaces of a titanium-coated polyether ether ketone (TCP) cage and a three-dimensional porous titanium alloy (PTA) cage following posterior lumbar interbody fusion (PLIF) until 1 year postoperatively.

Methods: A total of 59 patients who underwent one- or two-level PLIF for degenerative lumbar disorders since March 2015 were enrolled. Bone ongrowth of all cage frame surfaces (four surfaces per cage: TCP, 288 surfaces and PTA, 284 surfaces) was graded by 6-month and 1-year postoperative computed tomography color mapping (grade 0, 0‒25% of bone ongrowth; grade 1, 26‒50%; grade 2, 51‒75%; and grade 3, 76‒100%).

Results: Bone ongrowth (≥ grade 1) was observed on 58.0% and 69.0% of the surfaces of TCP and PTA cages 6 months postoperatively and on 63.5% and 75.0% of those 1 year postoperatively, respectively. In the TCP cages, bone ongrowth grade increased from 6 months to 1 year postoperatively only in the union segments (median, 1 [interquartile range, IQR, 0-2] to 1 [IQR, 0-3], p = 0.006). By contrast, in the PTA cages, it increased at 6 months postoperatively in the union (1 [IQR, 1-2] to 2 [IQR, 1-3], p = 0.003) and non-union (0.5 [IQR, 0-2] to 1 [IQR, 0-2.75], p = 0.002) segments.

Conclusion: Early postoperative mechanical stability has a positive impact on the progress of bone ongrowth on both the TCP and PTA cage frame surfaces after PLIF.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-020-06673-4DOI Listing

Publication Analysis

Top Keywords

bone ongrowth
28
frame surfaces
16
mechanical stability
12
progress bone
12
impact mechanical
8
stability progress
8
ongrowth frame
8
surfaces
8
surfaces titanium-coated
8
porous titanium
8

Similar Publications

Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.

Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.

View Article and Find Full Text PDF

Cementless fixation in total joint arthroplasty: Factors impacting osseointegration.

J Clin Orthop Trauma

February 2025

Orthopedic Surgery, Brigham & Women's Hospital, Harvard University, Boston, MA, USA.

•The success of cementless fixation in TJA depends on a multitude of factors including biological, mechanical, implant, surgical, and material properties.•Biologic fixation has become the primary mode of fixation for the majority of primary total hip arthroplasty (THA) surgeries done today in the United States (US) due to its low complication rate and superior longevity compared to cemented fixation.•Cementless fixation has yet to gain wider acceptance in total knee arthroplasty (TKA) and hip hemiarthroplasty due to several factors including host bone quality, implant design, and surgical technique.

View Article and Find Full Text PDF

Background: A novel pelvic fixation screw fusion device (iFuse Bedrock Granite implant) was designed to promote bony fusion through self-harvesting fenestrations throughout the outer screw shank. Bone on-growth and in-growth using this design have been demonstrated in a sheep model, but data from human subjects have not been reported. A 66-year-old medically complex female with 2 prior spine fusions developed spondylodiscitis cephalad to a prior fusion, requiring the removal of instrumentation, which included screw fusion devices.

View Article and Find Full Text PDF

Active osseointegration in an porcine bone model.

Front Bioeng Biotechnol

March 2024

Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom.

Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone.

View Article and Find Full Text PDF

Minimally invasive sacroiliac joint fusion has become increasingly prevalent and is described to reduce pain and improve function. In some patients, pain can recur several months after primary surgery. Lack of early implant osseointegration might be a cause of pain and hence an indication for revision surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!