A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aortic valve replacement in Germany in 2019. | LitMetric

Aims: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are established options to treat aortic valve stenosis. We present the outcome of the complete cohort of all patients undergoing SAVR or TAVI in Germany during the calendar year 2019.

Methods And Results: Data concerning all isolated aortic valve procedures performed in Germany in 2019 were retrieved from the mandatory nationwide quality control program: 22,973 transvascular (TV)-TAVI procedures, 7905 isolated SAVR (iSAVR), and 1413 transapical (TA)-TAVI. Data was complete in 99.9% (n = 32,156). In-hospital mortality after TV-TAVI (2.3%) was significantly lower when compared with iSAVR (2.8%, p = 0.007) or TA-TAVI (6.3%; p < 0.001). Expected mortality was calculated with a new version of the German Aortic valve score (AKL Score) based on the data of either catheter-based (AKL-CATH) or surgical (AKL-CHIR) aortic valve replacements in Germany in 2018. TV-TAVI and iSAVR both showed lower observed mortality in 2019 than expected based on their respective performance in 2018, yielding an observed/expected (O/E) mortality ratio < 1. This was particularly apparent for patients at low risk. After exclusion of emergency procedures, in-hospital mortality after TV-TAVI (2.1%) and after iSAVR (2.1%) was identical, even though patients undergoing TV-TAVI showed a considerably higher perioperative risk profile.

Conclusion: After excluding emergency procedures, in-hospital mortality of TV-TAVI and iSAVR in 2019 in Germany was identical. In 2019, TV-TAVI and iSAVR both show lower matched mortality ratios compared with 2018, which suggests technical improvements of both therapies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00392-020-01788-6DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
valve replacement
8
germany 2019
8
aortic
5
replacement germany
4
2019 aims
4
aims surgical
4
surgical aortic
4
valve
4
replacement savr
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!