Characterization of ferrous-agarose-xylenol gel dosimeter at Co γ-rays beam therapy unit.

Radiol Phys Technol

Secondary Standard Dosimetry Laboratory, Nuclear Research Center of Algiers, 02 Boulevard Frantz Fanon, B.P.399, Algiers, Algeria.

Published: March 2021

Fricke gel dosimetry is a valuable technique used for recording 3D dose distribution in radiotherapy. Herein, we present the dosimetric characteristics of a synthesized ferrous-agarose-xylenol orange gel dosimeter in a clinical Co beam. Experimental data were obtained using a secondary standards dosimetry laboratory Co therapy unit. The dosimeter was calibrated using the ionization chamber as a reference, and its total mass attenuation coefficient, absorption spectrum, optical density-dose relationship, sensitivity, and dose rate dependency were evaluated. The potentiality of the ferrous-agarose-xylenol gel dosimeter was investigated to measure output factors for different field sizes. The gel dosimeter readings were measured using a spectrophotometer. The ferrous-agarose-xylenol gel dosimeter exhibited a linearity in the range of 3-15 Gy, indicating that the dosimeter is tissue-equivalent and dose rate-independent and yield reproducible results. The measured output factors and those published in the literature showed good agreement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12194-020-00600-4DOI Listing

Publication Analysis

Top Keywords

gel dosimeter
20
ferrous-agarose-xylenol gel
12
therapy unit
8
output factors
8
dosimeter
7
gel
6
characterization ferrous-agarose-xylenol
4
dosimeter γ-rays
4
γ-rays beam
4
beam therapy
4

Similar Publications

A gamma cell unit is used for gamma irradiation of small volume samples. Due to the sample volume, there is a dose distribution, which is imperative to be known for appropriate irradiation. In this study, samples of agarose Fricke gel dosimeters were prepared for the dose mapping of the gamma cell unit available in our laboratory.

View Article and Find Full Text PDF

Background And Purpose: During an end-to-end (E2E) test on the online workflow of the MR-linac, the performance of the treatment starting from the acquisition of pre-treatment MRI scans and ending with dose delivery is quantified. In such a test, the geometrical accuracy of the entire workflow is assessed. Ideally, the 3D geometrical accuracy of dose delivery on an MR-linac should be assessed using dosimeters that provide 3D dose distributions.

View Article and Find Full Text PDF

Background: Comprehensive quality assurance (QA) for a seamless workflow of high-dose-rate brachytherapy, from imaging to planning and irradiation, is uncommon, and QA of the source dwell position is performed in one- or two-dimensions. Gel dosimetry using magnetic resonance imaging (MRI) is effective in verifying the three-dimensional distribution of doses for image-guided brachytherapy (IGBT). However, MRI scanners are not readily accessible, and MRI scanning is time-consuming.

View Article and Find Full Text PDF

Quantitative spatial visualization of X-ray irradiation via redox reaction by dynamic nuclear polarization magnetic resonance imaging.

Free Radic Biol Med

November 2024

Department of Radiology, Gifu University, Gifu, Japan; Innovation Research Center for Quantum Medicine, Gifu University, Gifu, Japan; Department of Radiology, Frontier Science for Imaging, School of Medicine, Gifu University, Gifu, Japan.

The dose of X-ray irradiation is commonly measured by point assessment with an ionization chamber dosimeter. However, to achieve spatially accurate delivery of X-ray to avoid the exposure to normal tissues, an accurate imaging method for spatially and quantitatively detecting exposure is required. Herein, we present a novel method to visualize X-ray exposure using low-field dynamic nuclear polarization magnetic resonance imaging (DNP-MRI) with nitroxyl radical tempol as the chemical dosimeter.

View Article and Find Full Text PDF
Article Synopsis
  • This study focuses on using a surfactant hydrogel dosimeter (SHD) to accurately measure 3D absorbed dose distributions in carbon ion radiotherapy, which is important for targeting tumors effectively.
  • The researchers set up a cubic target region and conducted carbon ion beam irradiation, measuring the response of the SHD using optical computed tomography to gather data about the absorbed dose.
  • Results showed that the optical attenuation coefficients (OAC) measured were lower than the expected absorbed dose, indicating discrepancies that may affect precise dosimetry in treatment planning.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!