Background: Radiofrequency ablation of epicardial and mid-myocardial ventricular arrhythmias is limited by lesion depth.
Objective: The purpose of this study was to generate deep mid-interventricular septal (IVS) lesions using high-intensity ultrasound (US) from an endocardial catheter-based approach.
Methods: Irrigated US catheters (12 F) were fabricated with 3 × 5 mm transducers of 5.0, 6.5, and 8.0 MHz frequencies and compared in an ex vivo perfused myocardial ablation model. In vivo septal ablation in swine (n = 12) was performed via femoral venous access to the right ventricle. Lesions were characterized by echocardiography, cardiac magnetic resonance imaging, and electroanatomic voltage mapping pre- and post-ablation, and at 30 days. Four animals were euthanized immediately post-ablation to compare acute and chronic lesion histology and gross pathology.
Results: In ex vivo models, maximal lesion depth and volume was achieved by 6.5 MHz catheters, which were used in vivo. Lesion depth by gross pathology was similar post-ablation (10.8 mm; 95% confidence interval [CI] 9.9-12.4 mm) and at 30 days (11.2 mm; 95% CI 10.6-12.4 mm) (P = .56). Lesion volume decreased post-ablation to 30 days (from 255 [95% CI 198-440] to 162 [95% CI 133-234] mm; P = .05), yet transmurality increased from 58% (95% CI 50%-76%) to 81% (95% CI 74%-93%), attributable to a reduction in IVS thickness (from 16.0 ± 1.7 to 10.6 ± 2.4 mm; P = .007). Magnetic resonance imaging confirmed dense septal ablation by delayed enhancement, with increased T1 time post-ablation and at 30 days and increased T2 time only post-ablation. Voltage mapping of both sides of IVS demonstrated reduced unipolar (but not bipolar) voltage along the IVS.
Conclusion: High-intensity US catheter ablation may be an effective treatment of mid-myocardial or epicardial ventricular arrhythmias from an endocardial approach.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8026528 | PMC |
http://dx.doi.org/10.1016/j.hrthm.2020.12.027 | DOI Listing |
Background: Continuous anticoagulation based on the CHA2DS2-VASc score is recommended to prevent embolism caused by atrial fibrillation (AF), but it does not consider AF episodes. The Apple Watch's continuous heart rhythm monitoring and fast-acting direct oral anticoagulants (DOACs) could enable precise, episode-tailored anticoagulation, reducing bleeding risks while preventing stroke. This study evaluates Apple Watch-guided personalized anticoagulation therapy, adjusting DOAC usage based on real-time AF detection.
View Article and Find Full Text PDFCureus
December 2024
Internal Medicine, Hurley Medical Center, Flint, USA.
Catheter ablation procedure for symptomatic atrial fibrillation is an established treatment. Cardiac tamponade is one of the several complications associated with atrial fibrillation ablation. We present the case of a 60-year-old male with a past medical history of end-stage renal disease (ESRD) on hemodialysis, hypotension on midodrine, atrial fibrillation status post-ablation a week prior, and a cerebrovascular accident who presented to the emergency department with complaints of weakness, nausea, vomiting, confusion and some syncopal episodes for the past few days.
View Article and Find Full Text PDFCancer Prev Detect Interv (2024)
October 2024
Magnetic resonance guided focused ultrasound (MRgFUS) is one of the most attractive emerging minimally invasive procedures for breast cancer, which induces localized hyperthermia, resulting in tumor cell death. Accurately assessing the post-ablation viability of all treated tumor tissue and surrounding margins immediately after MRgFUS thermal therapy residual tumor tissue is essential for evaluating treatment efficacy. While both thermal and vascular MRI-derived biomarkers are currently used to assess treatment efficacy, currently, no adequately accurate methods exist for the in vivo determination of tissue viability during treatment.
View Article and Find Full Text PDFPulsed Field Ablation (PFA) is a new ablation method being rapidly adopted for treatment of atrial fibrillation, which shows advantages in safety and efficiency over radiofrequency and cryo-ablation. In this study, we used an in vivo swine model (10 healthy and 5 with chronic myocardial infarct) for ventricular PFA, collecting intracardiac electrograms, electro-anatomical maps, native T1-weighted and late gadolinium enhancement MRI, gross pathology, and histology. We used 1000-1500 V pulses, with 1-16 pulse trains to vary PFA dose.
View Article and Find Full Text PDFPhlebology
December 2024
Department of Vascular Surgery, Texas Vascular and Imaging, Houston, TX, USA.
Objective: A single-center retrospective cohort study was conducted to identify potential risk factors that lead to increased incidence of intravascular coagulum (IC) observed in clinical practice using polidocanol endovenous microfoam (PEM 1%, Varithena [polidocanol injectable microfoam], Boston Scientific, Marlborough, Mass).
Methods: Patients ( = 119) who received polidocanol endovenous microfoam (PEM) treatment for chronic venous insufficiency between December 2021 and January 2024 at a private outpatient vascular surgery clinic were observed to identify potential risk factors in the development of IC. The patients were stratified into two groups: IC ( = 16) versus non-IC ( = 103).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!