Background And Aims: Post-prandial glucose control is essential to achieve metabolic goals in patients with type 1 diabetes mellitus (T1DM). The new «faster aspart» insulin has a pharmacological profile noted for its faster absorption and onset of action, and increased early availability, resulting in improved blood glucose control after meals. The main objective of the study was to analyse the efficacy of «faster aspart» vs. «insulin aspart» in children and adolescents with DM1 on sensor-augmented pump treatment.

Patients And Methods: Multicentre, longitudinal and prospective analytical trial evaluating the use of faster aspart insulin for three months in children with T1DM with MiniMed640G® sensor-augmented pumps previously treated with aspart insulin. At the beginning and end of the study the following variables were analysed for subsequent comparison: mean sensor glucose, percentage of time in range, hypoglycaemia and hyperglycaemia, area under the curve (AUC) < 70 and > 180 mg/dL, mean sensor glucose pre and postprandial in main meals, daily insulin requirements, basal/bolus percentage, and HbA1c. Acute complications, adverse events and satisfaction survey were assessed.

Results: The study included 31 patients with a mean of 13.49 ± 2.42 years of age and with T1DM of 7.0 ± 3.67 years of onset. The use of faster aspart was associated with lower time in hyperglycaemia > 180 mg/dL (25.8 ± 11.3 vs. 22.4 ± 9.5; p = 0.011) and > 250 mg/dL (5.2 ± 4.9 vs. 4.0 ± 3.6; p = 0.04), lower AUC > 180 mg/dL (10.8 ± 6.5 vs. 9.3 ± 6.1; p = 0.03), and increased time in range (71.4 ± 10.0 vs. 74.3 ± 9.2; p = 0.03). No significant changes in hypoglycaemia, HbA1c, insulin requirements, and basal/bolus percentages were detected. Faster aspart was safe and well-evaluated by patients and caregivers.

Conclusions: Faster aspart achieves better glycaemic control by increasing glucose time in range in children and adolescents with T1DM on treatment with sensor-augmented pumps.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anpedi.2020.11.002DOI Listing

Publication Analysis

Top Keywords

faster aspart
16
«faster aspart»
12
glucose control
12
children adolescents
12
time range
12
blood glucose
8
type diabetes
8
aspart insulin
8
sensor-augmented pumps
8
sensor glucose
8

Similar Publications

Insulin aspart, a rapid-acting analog, achieves faster subcutaneous absorption than regular insulin. This study aimed to demonstrate equivalence in the pharmacokinetic (PK) and pharmacodynamic (PD) characteristics of Recombinant Human Insulin Aspart from BioGenomics Limited (as test) and Novo-Nordisk (as reference) in healthy adult males. This was a double-blind, randomized, cross-over study, assessing PK and PD parameters under fasting conditions.

View Article and Find Full Text PDF

Aims: We compared sensor-derived glycaemic metrics in pregnant women with type 1 diabetes (T1D) randomised to faster acting insulin aspart (faster aspart) or insulin aspart (IAsp).

Methods: A pre-planned secondary analysis of the CopenFast trial included women with T1D using intermittently scanned continuous glucose monitoring (isCGM) during pregnancy. Glycaemic metrics, including time in range (TIRp, 3.

View Article and Find Full Text PDF

Introduction: We evaluated a potential move from one rapid-acting insulin analog to another, or their biosimilars, to aid better and faster decisions for diabetes management.

Methods: A systematic literature review was performed according to PRISMA reporting guidelines. The MEDLINE/EMBASE/COCHRANE databases were searched for randomized control trials (RCTs) comparing aspart/lispro in type-1 (T1D) and type-2 (T2D) diabetes.

View Article and Find Full Text PDF

Simple meal announcements and pramlintide delivery versus carbohydrate counting in type 1 diabetes with automated fast-acting insulin aspart delivery: a randomised crossover trial in Montreal, Canada.

Lancet Digit Health

July 2024

Department of Biomedical Engineering, McGill University, Montreal, QC, Canada; Division of Endocrinology, McGill University Health Centre, Montreal, QC, Canada; The Research Institute of McGill University Health Centre, Montreal, QC, Canada. Electronic address:

Background: In type 1 diabetes, carbohydrate counting is the standard of care to determine prandial insulin needs, but it can negatively affect quality of life. We developed a novel insulin-and-pramlintide closed-loop system that replaces carbohydrate counting with simple meal announcements.

Methods: We performed a randomised crossover trial assessing 14 days of (1) insulin-and-pramlintide closed-loop system with simple meal announcements, (2) insulin-and-placebo closed-loop system with carbohydrate counting, and (3) insulin-and-placebo closed-loop system with simple meal announcements.

View Article and Find Full Text PDF

Effectiveness of Faster Aspart versus Insulin Aspart in Children with Type 1 Diabetes: A Meta-Analysis.

Iran J Public Health

January 2024

Department of Outpatient, The First People's Hospital of Huzhou, First Affiliated Hospital of Huzhou Normal University, Huzhou 313000, Zhejiang Province, China.

Background: Intensive insulin regimens are recommended to achieve glycemic goals in children and adolescents with type 1 diabetes. Fast-acting insulin aspart (faster aspart) is a new formulation of insulin aspart (IAsp) in which L-arginine and niacinamide are added to assure formulation stability, early absorption, and ultra-fast action. This meta-analysis compares faster aspart with IAsp for blood sugar control in children with type 1 diabetes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!