A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Durability of Hydrophobic/Icephobic Coatings in Protection of Lightweight Concrete with Waste Aggregate. | LitMetric

Durability of Hydrophobic/Icephobic Coatings in Protection of Lightweight Concrete with Waste Aggregate.

Materials (Basel)

Faculty of Environmental Engineering, Lublin University of Technology, Nadbystrzycka 40 B, 20-618 Lublin, Poland.

Published: December 2020

The aim of the research presented in this paper is to evaluate the feasibility of using hydrophobic agents based on organosilicon compounds for surface protection of lightweight concrete modified with waste polystyrene. The experimental part pertains to the physical and mechanical properties of polystyrene-modified lightweight concrete. The concrete samples were prepared with the following ingredients: CEM I 42.5 R cement, recycled polystyrene (0-2 mm), quartz sand (0-2 mm), coarse river aggregate (2-16 mm), and water. Silane and tetramethoxysilane were employed for surface hydrophobization. Concrete with 20% polystyrene exhibits high porosity (25.22%), which is related to an increase in absorptivity (14.75%) compared to the reference concrete. The hydrophobized concrete is characterized by the lowest surface free energy (SFE) value, which is 7 or 11 times lower than the value of reference concrete, depending on the agents. The test on the contact angle (CA) was performed before and after the frost-resistance test (F-T test). Lower SFE translates into lower adhesive properties, higher resistance of the material to the infiltration of water and corrosive compounds, e.g., salts, and higher resistance to freezing and thawing cycles. Silane and tetramethoxysilane coating raised frost resistance by 54-58% compared to the reference samples. This agent reduced absorptivity by 30%. Recycled polystyrene can be successfully used to produce lightweight concrete (LC) with high durability provided by hydrophobic/icephobic coatings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795289PMC
http://dx.doi.org/10.3390/ma14010101DOI Listing

Publication Analysis

Top Keywords

lightweight concrete
16
concrete
9
hydrophobic/icephobic coatings
8
protection lightweight
8
recycled polystyrene
8
silane tetramethoxysilane
8
compared reference
8
reference concrete
8
higher resistance
8
durability hydrophobic/icephobic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!