Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The free sulfhydryl groups of the hinge region of monovalent antibody fragments (rIgG) allow the orientation of rIgG on functionalized surfaces in immunosensors. To evaluate the contribution of reduction and orientation on signal enhancement we compared the performance of whole antibodies and their rIgG in ELISA performed on polystyrene or maleimide-functionalized microplates. Monoclonal anti-horseradish peroxidase (anti-HRP) and monoclonal anti-fPSA antibodies (1 mg/mL) were reduced with 2-mercaptoethylamine (53 mM). Western blot confirmed the presence of rIgG as a band at 75 kDa, detectable only by anti-heavy chain but not by anti-light chain antibodies, suggesting a possible folding rearrangement. Using anti-HRP we confirmed the retention of the antigen binding capacity of rIgG. Moreover, we observed a signal enhancement for rIgG even if randomly absorbed on polystyrene [linear regression slope (95%CI): rIgG 0.524 (0.434-0.614), IgG 0.370 (0.430-0.399); P = 0.0016] suggesting that chemical reduction might affect the antigen binding capacity of antibodies. ELISA with anti-fPSA rIgG coated on polystyrene confirmed these observations. Oriented anti-fPSA rIgG on a maleimide surface showed comparable signals to the assay performed on polystyrene for each analyzed concentration of antigen (P = 0.1980), anyway, with a significant improvement of the repeatability likely providing a more homogeneous capturing surface (SD rIgG-rIgG: fPSA 0.725 ng/mL:0.74-2.89; 1.45 ng/mL:1.56-8.69; 3.625 ng/mL:3.52-15.03; 7.25 ng/mL:7.78-18.44).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2020.114090 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!