A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Prospective Audit of Airway Code Activations and Adverse Events in Two Tertiary Hospitals. | LitMetric

A Prospective Audit of Airway Code Activations and Adverse Events in Two Tertiary Hospitals.

Ann Acad Med Singap

Department of Anaesthesiology, Division of Anaesthesiology and Perioperative Sciences, Singapore General Hospital, Singapore.

Published: November 2020

Introduction: Airway management outside the operating room can be challenging, with an increased risk of difficult intubation, failed intubation and complications. We aim to examine airway practices, incidence of difficult airway and complications associated with airway code (AC) activation.

Methods: We conducted a prospective audit of AC activations and adverse events in two tertiary hospitals in Singapore. We included all adult patients outside the operating room who underwent emergency intubation by the AC team after AC activation. Adult patients who underwent emergency intubation without AC activation or before the arrival of the AC team were excluded. Data were collected and documented by the attending anaesthetists in a standardised survey form shortly after their responsibilities were completed.

Results: The audit was conducted over a 20-month period from July 2016 to March 2018, during which a total of 224 airway activations occurred. Intubation was successful in 218 of 224 AC activations, giving a success rate of 97.3%. Overall, 48 patients (21.4%) suffered an adverse event. Thirteen patients (5.8%) had complications when intubation was carried out by the AC team compared with 35 (21.5%) by the non-AC team.

Conclusion: Dedicated AC team offers better success rate for emergency tracheal intubation. Non-AC team attempted intubation in the majority of the cases before the arrival of the AC team. Increased intubation attempts are associated with increased incidence of adverse events. Equipment and patient factors also contributed to the adverse events. A multidisciplinary programme including the use of supraglottic devices may be helpful to improve the rate of success and minimise complications.

Download full-text PDF

Source
http://dx.doi.org/10.47102/annals-acadmedsg.2020242DOI Listing

Publication Analysis

Top Keywords

adverse events
16
intubation
9
prospective audit
8
airway code
8
activations adverse
8
events tertiary
8
tertiary hospitals
8
operating room
8
adult patients
8
underwent emergency
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!