Ventilator dyssynchrony - Detection, pathophysiology, and clinical relevance: A Narrative review.

Ann Thorac Med

Department of Medicine, Division of Pulmonary Sciences and Critical Care Medicine, University of Colorado School of Medicine, Aurora, Colorado, USA.

Published: October 2020

Mortality associated with the acute respiratory distress syndrome remains unacceptably high due in part to ventilator-induced lung injury (VILI). Ventilator dyssynchrony is defined as the inappropriate timing and delivery of a mechanical breath in response to patient effort and may cause VILI. Such deleterious patient-ventilator interactions have recently been termed patient self-inflicted lung injury. This narrative review outlines the detection and frequency of several different types of ventilator dyssynchrony, delineates the different mechanisms by which ventilator dyssynchrony may propagate VILI, and reviews the potential clinical impact of ventilator dyssynchrony. Until recently, identifying ventilator dyssynchrony required the manual interpretation of ventilator pressure and flow waveforms. However, computerized interpretation of ventilator waive forms can detect ventilator dyssynchrony with an area under the receiver operating curve of >0.80. Using such algorithms, ventilator dyssynchrony occurs in 3%-34% of all breaths, depending on the patient population. Moreover, two types of ventilator dyssynchrony, double-triggered and flow-limited breaths, are associated with the more frequent delivery of large tidal volumes >10 mL/kg when compared with synchronous breaths (54% [95% confidence interval (CI), 47%-61%] and 11% [95% CI, 7%-15%]) compared with 0.9% (95% CI, 0.0%-1.9%), suggesting a role in propagating VILI. Finally, a recent study associated frequent dyssynchrony-defined as >10% of all breaths-with an increase in hospital mortality (67 vs. 23%, = 0.04). However, the clinical significance of ventilator dyssynchrony remains an area of active investigation and more research is needed to guide optimal ventilator dyssynchrony management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7720746PMC
http://dx.doi.org/10.4103/atm.ATM_63_20DOI Listing

Publication Analysis

Top Keywords

ventilator dyssynchrony
44
ventilator
13
dyssynchrony
10
narrative review
8
lung injury
8
types ventilator
8
interpretation ventilator
8
associated frequent
8
dyssynchrony detection
4
detection pathophysiology
4

Similar Publications

Effect of total intravenous anesthesia versus sevoflurane anesthesia on intraoperative facial nerve monitoring: a randomized controlled trial.

Can J Anaesth

November 2024

Department of Anesthesiology and Pain Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro Gangnam-gu, Seoul, 06351, Republic of Korea.

Purpose: Intraoperative facial nerve monitoring (IFNM) facilitates effective nerve preservation during ear and head and neck surgeries. Quantitative differences in the timely feasibility of IFNM during total intravenous anesthesia (TIVA) vs sevoflurane anesthesia have not been investigated.

Methods: We conducted a randomized controlled trial in which 98 patients undergoing ear surgery were allocated to either the TIVA or sevoflurane group.

View Article and Find Full Text PDF

Does patient-ventilator asynchrony really matter?

Curr Opin Crit Care

February 2025

Keenan Centre for Biomedical Research, Li Ka Shing Knowledge Institute, Unity Health Toronto.

Purpose Of Review: Past observational studies have reported the association between patient-ventilator asynchronies and poor clinical outcomes, namely longer duration of mechanical ventilation and higher mortality. But causality has remained undetermined. During the era of lung and diaphragm protective ventilation, should we revolutionize our clinical practice to detect and treat dyssynchrony?

Recent Findings: Clinicians' ability to recognize asynchronies is typically low.

View Article and Find Full Text PDF

Neuromuscular Blockade in Adult Respiratory Distress Syndrome.

Clin Chest Med

December 2024

Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Dr. E Borges Road, Mumbai, Maharashtra 400012, India.

Although current clinical practice guidelines have discordant conclusions, a judicious approach to using NMBA infusions may include reserving their use for patients with early severe ARDS who are already deeply sedated and for patients under light sedation who have significant ventilator dyssynchrony, despite attempts to adjust both ventilator settings and sedation requirements. Based on current evidence, the duration of NMBA use should be limited to 48 hours, whenever possible.

View Article and Find Full Text PDF

Phrenic nerve stimulation is currently being investigated for the prevention of diaphragm atrophy in patients with mechanically supported breathing. Patients receiving breathing support from mechanical ventilation are at risk of mismatches between respiratory demand and ventilator support. Our objectives were to determine if a novel phrenic nerve stimulation device provided stimulation during inspiration as intended and did not exacerbate any potential discordances.

View Article and Find Full Text PDF
Article Synopsis
  • Depth electroencephalography (dEEG) is an advanced technique used to monitor brain activity in patients with acute brain injuries, allowing for the detection of nonconvulsive seizures (NCSzs) that might not be seen on traditional scalp EEG.
  • In a study of 33 adults, a significant number (about 66%) showed highly epileptiform patterns, but only 27% of those with electrographic seizures had clear scalp correlates; subtle clinical signs were observed during seizures.
  • The findings suggest that while many critical patients experience NCSzs, these seizures can often go unnoticed by standard EEG monitoring, highlighting the need for more sensitive detection methods in clinical settings.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!