The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/5.0014207 | DOI Listing |
Electromagn Biol Med
January 2025
Department of Mathematics, University of Gour Banga, Malda, India.
Biomagnetic fluid dynamics (BFD) is an emerging and promising field within fluid mechanics, focusing on the dynamics of bio-fluids like blood in the presence of magnetic fields. This research is crucial in the medical arena for applications such as medication delivery, diagnostic and therapeutic procedures, prevention of excessive bleeding, and treatment of malignant tumors using magnetic particles. This study delves into the intricacies of blood flow induced by cilia, carrying trihybrid nanoparticles (gold, copper, and titania), within a catheterized arterial annulus under a robust magnetic field.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Medical School, Faculty of Medicine, Tianjin University, Tianjin 300072, China.
Multispectral transmission imaging has emerged as a promising technique for imaging breast tissue with high resolution. However, the method encounters challenges such as low grayscale, noisy transmission images with weak signals, primarily due to the strong absorption and scattering of light in breast tissue. A common approach to improve the signal-to-noise ratio (SNR) and overall image quality is frame accumulation.
View Article and Find Full Text PDFNanophotonics
April 2024
Department of Bio-Functions and Systems Science, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 Japan.
Metasurface holograms offer various advantages, including wide viewing angle, small volume, and high resolution. However, full-color animation of high-resolution images has been a challenging issue. In this study, a full-color dielectric metasurface holographic movie with a resolution of 2322 × 2322 was achieved by spatiotemporally multiplexing 30 frames with blue, green, and red color channels at the wavelengths of 445 nm, 532 nm, and 633 nm at the maximum reconstruction speed of 55.
View Article and Find Full Text PDFJ Acoust Soc Am
December 2024
Graduate School of Frontier Sciences, The University of Tokyo, Kashiwa, Japan.
Airborne ultrasound phased arrays (AUPAs) generate non-contact tactile sensations and enable acoustic levitation with specific focus fields. Using multiple units together offers numerous advantages, such as increased stimulus intensity and the ability to overcome occlusion. The AUPA units are typically mounted on a fixed frame, with their poses manually measured using tools such as a ruler for calibration.
View Article and Find Full Text PDFJ Crohns Colitis
November 2024
Department of Translational Research in Gastrointestinal Diseases (TARGID), KU Leuven, Leuven, Belgium.
Introduction: Ulcerative colitis (UC) management employs a strategy targeting histological and endoscopic remission. Correlation of white-light endoscopy (WLE) scores with histological activity is limited. Single-wavelength endoscopy (SWE) addressing microvascular changes reflecting histological disease activity, may better assess histological remission.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!