We present a wavelength meter with picometer-scale resolution based on etaloning effects of inexpensive glass slides and the built-in color filters of a consumer grade CMOS camera. After calibrating the device to a commercial meter, we tested the device's calibration stability using two tunable visible lasers for a period of over 16 days. The wavelength error over that entire period has a standard deviation of 5.29 parts per million (ppm) about a most probable error of 0.90 ppm. Within 24 hours of calibration, this improves to 0.04 ppm with a standard deviation of 3.94 ppm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.409466DOI Listing

Publication Analysis

Top Keywords

standard deviation
8
laser wavelength
4
wavelength metrology
4
metrology low-finesse
4
low-finesse etalons
4
etalons bayer
4
bayer filters
4
filters wavelength
4
wavelength meter
4
meter picometer-scale
4

Similar Publications

The fluorescence detection of amino compounds and the evaluation of their content in environmental samples are vital, not only for assessing food quality but also for studying soil organic matter. Here, we present the synthesis and application of a novel fluorescent probe, 4-(9-acridone)benzylmethyl carbonochloride (APE-Cl), for detecting amino compounds via a chloroformate reaction with fluorescence detection. The complete derivatization reaction of APE-Cl with amino compounds can be accomplished in aqueous acetonitrile within 5 min at room temperature, using 0.

View Article and Find Full Text PDF

Association Between Diagnostic Delay and Economic and Clinical Burden in Axial Spondyloarthritis: A Multicentre Retrospective Observational Study.

Rheumatol Ther

January 2025

Rheumatology Department, Parc Taulí University Hospital. Institut d'Investigació i Innovació Parc Taulí (I3PT-CERCA), Universitat Autònoma de Barcelona, Parc Taulí, 1, Sabadell, 08208, Barcelona, Spain.

Introduction: Axial spondyloarthritis (axSpA) is a chronic inflammatory condition associated with considerable pain and impaired health-related quality of life (HRQoL) for affected patients. Despite the documented increase in healthcare resource utilization (HRU) related to axSpA, few studies have explored the impact of diagnostic delays on these outcomes. This study sought to determine the association between diagnostic delay of axial spondyloarthritis (axSpA) and costs in the 3 years after diagnosis.

View Article and Find Full Text PDF

Temporomandibular joint septic arthritis: a report of thirteen cases and a systematic review of the literature.

Rheumatol Int

January 2025

Department of Oral and Maxillofacial Surgery, U1008 - Advanced Drug Delivery Systems, Univ. Lille, CHU Lille, INSERM, Lille, F-59000, France.

Introduction: Temporomandibular joint (TMJ) septic arthritis is a rare frequently misdiagnosed condition with non-specific symptoms. We present our experience of thirteen cases of TMJ septic arthritis and perform a systematic review of the literature to collate the multiple characteristics of this condition.

Material And Method: A total of 133 cases of TMJ septic arthritis in humans across 62 studies were analyzed by searching PubMed, Cochrane Library, DOAJ and ClinicalTrials.

View Article and Find Full Text PDF

Objective: This study aimed to analyze the influence of different tunnel reinforcement measures on drivers and to evaluate the associated driving safety risks.

Methods: Experimental data of driving behavior and physiological response were collected under different driving simulation scenarios, such as cover arch erection, corrugated steel, grouting, Steel strips, and fire; an evaluation index system was established based on electrocardiographic (ECG), electrodermal activity(EDA), standard deviation of speed (SDSP), Steering Entropy(SE), standard deviation of lateral position (SDLP) and other indices. The classical domain rank standard of each evaluation index was divided using K-Means algorithm, and a synthetic evaluation matter-element model was established to comprehensively evaluate and analyze the safety risks of each scenario.

View Article and Find Full Text PDF

We investigated associations of menopausal age category with body mass index (BMI), waist circumference, waist-hip ratio, and waist-height ratio. We also explored the moderating effect of anthropometric measures on associations of menopausal age category with prespecified sex hormones: estradiol, dehydroepiandrosterone (DHEA), sex hormone-binding globulin, bioavailable testosterone, and total testosterone-estradiol (T/E) ratio. In this cross-sectional study, we included 2,436 postmenopausal women from the Multi-Ethnic Study of Atherosclerosis who had menopausal age, anthropometric, and sex hormone data at baseline.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!