Problems of constructing an adaptive optical system intended for correcting the wavefront of laser radiation that has passed through a turbulent atmosphere are considered. To ensure high-quality wavefront correction, the frequency of the discrete system should be at least 1 kHz or more. This performance can be achieved by using FPGA as the main control element of the system. The results of a laboratory experiments of the laser beam phase fluctuations caused by turbulence, produced by the airflow of a fan heater, correction by means of the FPGA-based adaptive optical system are presented. The system efficiency was evaluated at various correction frequencies up to 1875 Hz.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.409201DOI Listing

Publication Analysis

Top Keywords

adaptive optical
12
optical system
12
system
6
real-time khz
4
khz adaptive
4
system correct
4
correct atmospheric
4
atmospheric turbulence
4
turbulence problems
4
problems constructing
4

Similar Publications

Syncopal reactions in blood donors: Pathophysiology, clinical course, and features.

Asian J Transfus Sci

September 2022

Department of Physiology, Mahatma Gandhi Medical College, Sri Balaji Vidyapeeth (Deemed to be University), Puducherry, India.

Vasovagal syncope (VVS) in donors is a transient loss of consciousness due to short-term global cerebral hypoperfusion, which has a rapid onset and has complete spontaneous recovery. VVS may be triggered by pain, fear, anxiety, or emotional upset and loss of blood perse. It is an exaggeration of an adaptive response meant to assist in reducing the amount of bleeding/loss of blood.

View Article and Find Full Text PDF

Introduction: We explored associations between measurements of the ocular choroid microvasculature and Alzheimer's disease (AD) risk.

Methods: We measured the choroidal vasculature appearing in optical coherence tomography (OCT) scans of 69 healthy, mid-life individuals in the PREVENT Dementia cohort. The cohort was prospectively split into low-, medium-, and high-risk groups based on the presence of known risk factors (apolipoprotein E [] ε4 genotype and family history of dementia [FH]).

View Article and Find Full Text PDF

Monoelemental calibration solutions are the most common reference in elemental analysis, linking measurement results to the International System of Units (SI). National Metrology Institutes (NMI) prepare these solutions as certified reference materials (CRM) and determine their elemental mass fraction with high accuracy. Characterization with high accuracy is one of the most critical steps in CRM production.

View Article and Find Full Text PDF

Purpose: To determine how Hardy-Rand-Rittler (HRR) colour vision testing correlates with visual functional and structural assessments in Cone and Cone-Rod Dystrophy.

Methods: Thirty-four Cone and 69 Cone-Rod Dystrophy patients diagnosed by electroretinography (ERG) at the Save Sight Institute in Sydney were included in a retrospective analysis. Each patient's HRR colour vision test scores were compared with markers of cone and rod system function including visual acuity (VA), ERG responses, changes on Spectral Domain Optical Coherence Tomography (OCT) and Fundus Autofluorescence.

View Article and Find Full Text PDF

Traumatic optic neuropathy (TON) is a common cause of irreversible blindness following head injury. TON is characterized by axon damage in the optic nerve followed by retinal ganglion cell death in the days and weeks following injury. At present, no therapeutic or surgical approach has been found to offer any benefit beyond observation alone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!