A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aptamer selection and aptasensor construction for bone density biomarkers. | LitMetric

Aptamer selection and aptasensor construction for bone density biomarkers.

Talanta

Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Rd, Riyadh, 11533, Saudi Arabia; Department of Biochemistry and Molecular Medicine, College of Medicine, Alfaisal University, Riyadh, Saudi Arabia. Electronic address:

Published: March 2021

Osteoporosis (OP) is a bone disease involved in dysregulation of one of the bone metabolism arms, formation, or desorption cause a porous bone. Osteocalcin (OC) and beta-crosslap (BC), are the well-known markers for OP, which are connected to bone formation and desorption, respectively. In addition to the OP biomarker, BC is also used as an estrogen replacement therapeutic monitoring. ELISA and other antibody-based detection methods are routinely used for measuring OC and BC. These methods have limitations that include thermostability, sensitivity, sacrificing animals, and cost of production. However, aptamer-based-assays are of interest to overcome these drawbacks and achieve the most specific and robust application. Herein, specific aptamers for OC and BC were selected by the systematic evolution of ligands by exponential enrichment (SELEX) method from the pool of ssDNA library with 60 random sequences. The binding affinity (K) of the selected aptamers were evaluated against the respective biomarkers. The high-affinity aptamers of OC and BC showed the K values of 59 and 55 nM respectively. A graphene oxide-based aptasensors were fabricated from the high-affinity aptamers, and the detection limits of OC and BC were found to be 0.4 pg/ml and 0.21 pg/ml, respectively. These aptasensors have been tested with OC and BC spiked buffer samples and validated using serum samples collected from osteoporotic rats.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2020.121818DOI Listing

Publication Analysis

Top Keywords

formation desorption
8
high-affinity aptamers
8
bone
5
aptamer selection
4
selection aptasensor
4
aptasensor construction
4
construction bone
4
bone density
4
density biomarkers
4
biomarkers osteoporosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!