A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Stereotactic Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards. | LitMetric

Purpose: We sought to investigate the tumor control probability (TCP) of vestibular schwannomas after single-fraction stereotactic radiosurgery (SRS) or hypofractionated SRS over 2 to 5 fractions (fSRS).

Methods And Materials: Studies (PubMed indexed from 1993-2017) were eligible for data extraction if they contained dosimetric details of SRS/fSRS correlated with local tumor control. The rate of tumor control at 5 years (or at 3 years if 5-year data were not available) were collated. Poisson modeling estimated the TCP per equivalent dose in 2 Gy per fraction (EQD2) and in 1, 3, and 5 fractions.

Results: Data were extracted from 35 publications containing a total of 5162 patients. TCP modeling was limited by the absence of analyzable data of <11 Gy in a single-fraction, variability in definition of "tumor control," and by lack of significant increase in TCP for doses >12 Gy. Using linear-quadratic-based dose conversion, the 3- to 5-year TCP was estimated at 95% at an EQD2 of 25 Gy, corresponding to 1-, 3-, and 5-fraction doses of 13.8 Gy, 19.2 Gy, and 21.5 Gy, respectively. Single-fraction doses of 10 Gy, 11 Gy, 12 Gy, and 13 Gy predicted a TCP of 85.0%, 88.4%, 91.2%, and 93.5%, respectively. For fSRS, 18 Gy in 3 fractions (EQD2 of 23.0 Gy) and 25 Gy in 5 fractions (EQD2 of 30.2 Gy) corresponded to TCP of 93.6% and 97.2%. Overall, the quality of dosimetric reporting was poor; recommended reporting guidelines are presented.

Conclusions: With current typical SRS doses of 12 Gy in 1 fraction, 18 Gy in 3 fractions, and 25 Gy in 5 fractions, 3- to 5-year TCP exceeds 91%. To improve pooled data analyses to optimize treatment outcomes for patients with vestibular schwannoma, future reports of SRS should include complete dosimetric details with well-defined tumor control and toxicity endpoints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9477217PMC
http://dx.doi.org/10.1016/j.ijrobp.2020.11.019DOI Listing

Publication Analysis

Top Keywords

tumor control
20
stereotactic radiosurgery
8
vestibular schwannomas
8
control probability
8
recommended reporting
8
dosimetric details
8
5-year tcp
8
fractions eqd2
8
tcp
7
tumor
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!