Objectives: To evaluate the reliability of the OMERACT paediatric ultrasound (US) synovitis definitions and scoring system in JIA.

Methods: Thirteen sonographers analysed 75 images for the presence/absence of elementary lesions (binary scoring) and for grading synovitis, synovial hypertrophy, effusion and Doppler signals. Static US images of the second metacarpophalangeal joint (MCP-II), wrist, elbow, knee and ankle in JIA patients at different ages and different disease stages were collected with standardized scanning by two experienced sonographers. Intra- and inter-reader reliability were analysed with kappa coefficients.

Results: Intra-reader reliability was good for binary scoring (Cohen's kappa 0.62, range 0.47-0.75), synovitis and synovial hypertrophy; excellent for Doppler signals (quadratic weighted kappa 0.77, 0.66-0.86; 0.76, 0.61-0.84; and 0.87, 0.77-0.94, respectively); and moderate for effusion (0.55, 0.24-0.76). Inter-reader reliability was good for synovitis and synovial hypertrophy (Light's kappa 0.68, 95% CI: 0.61, 0.75 and 0.63, 0.54-0.71, respectively), excellent for Doppler signals (0.85, 95% CI: 0.77, 0.90), and moderate for binary scoring and effusion (0.48, 95% CI: 0.36, 0.64 and 0.49, 0.40-0.60, respectively). We obtained the best scores for the knee (0.71, 0.54-0.85) except for Doppler signals, with reliability higher for MCP-II. We found a trend toward better results in older children.

Conclusions: This is the first study establishing the reliability of the OMERACT paediatric US synovitis definitions and scoring system in the five most commonly affected joints in JIA. The reliability was good among a large group of sonographers. These results support the applicability of these definitions and scoring system in clinical practice and multicentre studies.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rheumatology/keaa804DOI Listing

Publication Analysis

Top Keywords

scoring system
16
doppler signals
16
definitions scoring
12
binary scoring
12
synovitis synovial
12
synovial hypertrophy
12
reliability good
12
reliability
8
reliability omeract
8
omeract paediatric
8

Similar Publications

Background: We aimed to assess impairments on health-related quality of life, and mental health resulting from Retinal artery occlusion (RAO) with monocular visual field loss and posterior circulation ischemic stroke (PCIS) with full or partial hemianopia using patient-reported outcome measures (PROMs).

Methods: In a prospective study, consecutive patients with acute RAO on fundoscopy and PCIS on imaging were recruited during their surveillance on a stroke unit over a period of 15 months. Baseline characteristics were determined from medical records and interviews.

View Article and Find Full Text PDF

The Geriatric Nutritional Risk Index (GNRI) is an effective tool for identifying malnutrition, and helps monitor the prognosis of patients undergoing maintenance hemodialysis. However, the association between the GNRI and cardiovascular or all-cause mortality in hemodialysis patients remains unclear. Therefore, this study investigated the correlation of the GNRI with all-cause and cardiovascular mortality in patients undergoing maintenance hemodialysis.

View Article and Find Full Text PDF

Diabetes is a chronic lifelong condition that requires consistent self-care and daily lifestyle adjustments. Effective disease management involves regular blood glucose monitoring and ongoing nursing support. Inadequate education and poor self-management are key factors contributing to increased mortality among diabetic individuals.

View Article and Find Full Text PDF

An Iterative Design Method for Advancing Air Traffic Control and Management Training Through Immersive VFR 3D Map Visualization.

IISE Trans Occup Ergon Hum Factors

January 2025

The Bradley Department of Electrical and Computer Engineering, College of Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA.

OCCUPATIONAL APPLICATIONSInnovative tools that align with modern learners' preferences are essential for training in safety-critical professions like Air Traffic Control/Management. This study evaluated a Virtual Reality Visual Flight Rules 3D Map Visualization Tool designed to meet the Federal Aviation Administration's (FAA) modernization goals. The tool immerses trainee in contextually accurate environments, enhancing engagement and self-paced learning.

View Article and Find Full Text PDF

Introduction: The Society for Pediatric Anesthesia Quality and Safety Committee developed the Pediatric Regional Anesthesia Time-Out Checklist, consisting of 14 safety items intended to be reviewed by an anesthesia team prior to a regional anesthetic. Primarily, we hypothesized that use of this Checklist would increase the number of safety items performed compared with no checklist, evaluating the usefulness of this tool. Secondarily, we hypothesized that, after checklist training, subjects would show better clinical judgment by electing to perform a regional anesthetic in scenarios in which no programmed error existed and electing to not perform a regional anesthetic in scenarios in which a programmed error did exist.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!