We report a case of temporary pacemaker lead malposition in the left ventricle crossing the interventricular septum (IVS). The majority of described cases occur due to a patent foramen ovale and are frequently incidental findings. A course across the IVS is rarely found and this complication with temporary leads is not even reported in the literature. This very rare location entails a risk of dangerous complications associated with left-to-right flow after lead removal. Echocardiography was an essential tool to diagnose the lead's course inside the heart and enabled secure removal of the lead with cardiac surgery backup.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.repc.2020.12.006DOI Listing

Publication Analysis

Top Keywords

temporary pacemaker
8
left ventricular
4
ventricular pacing
4
pacing temporary
4
pacemaker case
4
case report
4
report report
4
report case
4
case temporary
4
pacemaker lead
4

Similar Publications

Background: Atrial infarction is a complication of myocardial infarction with ventricular infarction; however, isolated atrial infarction (IAI) has rarely been reported. Herein, we report a case of IAI associated with sick sinus syndrome and atrial fibrillation (AF).

Case Summary: An 83-year-old woman was brought to the emergency department with a complaint of general malaise.

View Article and Find Full Text PDF

Background: This case report highlights the conduction disorder anomalies associated with dengue infection, particularly bradyarrhythmias due to dysfunction of the sinus node and atrioventricular node, which may require cardiac stimulation such as pacemaker implantation. This case emphasizes the importance of continuous monitoring and the use of additional diagnostic techniques to detect complications in a timely manner.

Case Summary: A 31-year-old male patient was admitted to our institution with symptoms of dyspnoea, orthopnoea, and severe bradycardia.

View Article and Find Full Text PDF

Purpose: Increasing life expectancy and advances in cancer treatment will lead to more patients needing both radiation therapy (RT) and cardiac implantable electronic devices (CIEDs). CIEDs, including pacemakers and defibrillators, are essential for managing cardiac arrhythmias and heart failure. Telemetric monitoring of CIEDs checks battery status, lead function, settings, and diagnostic data, thereby identifying software deviations or damage.

View Article and Find Full Text PDF

Temporary Transvenous Pacing Performed in the Intensive Care Unit or in the Catheterization Laboratory.

Pacing Clin Electrophysiol

January 2025

Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.

Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.

Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.

View Article and Find Full Text PDF