A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combination of InnoSEAL plus TR band compared with TR band alone for radial artery outcomes in patients undergoing transradial coronary intervention (InnoSEAL-II): an open-label randomised controlled trial (protocol). | LitMetric

Introduction: About 2%-30% of cardiac catheterisation procedures get complicated by radial artery occlusion (RAO). Ensuring patent haemostasis appears to be an important factor in reducing RAO. Currently employed method is a radial compression device (RCD) such as transradial band (TRB) that take hours to achieve haemostasis and cause discomfort to the patients. Haemostatic pads offer an alternative to RCD with reduced time to achieve haemostasis. Our trial aims to determine the non-inferiority of the catecholamine chitosan-based pad (InnoSEAL haemostatic pad) used in conjunction with TRB (InnoSEAL +TRB) when compared with the TRB alone in reducing composite adverse access site outcomes.

Methods And Analysis: It will be an open-label, parallel, randomised controlled trial on 714 adult patients (325 in each arm) undergoing coronary procedure using transradial approach at a cardiac health facility over 7 months duration. InnoSEAL patch along with TRB will be used to control bleeding in intervention arm and TRB alone in control arm, which is the standard practice. Study primary outcomes include RAO and haematoma; secondary outcomes are compression time, patient discomfort, time to discharge and ease of use of the intervention technique by the healthcare staff. χ test will be used to compare the categorical outcomes between two arms and student's t-test for continuous outcomes. A p value of <0.05 will be considered significant.

Ethics And Dissemination: Ethical approval for the study has been obtained from the Institutional Review Board of Tabba Heart Institute number IORG0007863. Findings will be disseminated through seminars and scientific publications.

Trial Registration Number: NCT04380883; Pre-results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7759964PMC
http://dx.doi.org/10.1136/bmjopen-2020-042101DOI Listing

Publication Analysis

Top Keywords

radial artery
8
randomised controlled
8
controlled trial
8
achieve haemostasis
8
outcomes
5
trb
5
combination innoseal
4
innoseal band
4
band compared
4
compared band
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!