Objective: Data regarding the ability of antidepressants to enter fetal, newborn and infant fluids have become gradually available, but mechanisms of antidepressant transfer remain poorly understood. Here we calculated penetration ratios in an array of matrices from combined samples of pregnant/breastfeeding women taking antidepressants.
Method: We performed a systematic literature search of PubMed and EMBASE to identify studies with concentrations of antidepressants from maternal blood, amniotic fluid, umbilical cord blood and/or breast milk. Penetration ratios were calculated by dividing the concentrations in amniotic fluid, umbilical cord plasma or breast milk by the maternal plasma concentration. When data from multiple studies were available, we calculated combined penetration ratios, weighting the study mean by study size.
Results: Eighty-five eligible studies were identified. For amniotic fluid, the highest penetration ratios were estimated for venlafaxine (mean 2.77, range 0.43-4.70 for the active moiety) and citalopram (mean 2.03, range 0.35-6.97), while the lowest ratios were for fluvoxamine (mean 0.10) and fluoxetine (mean 0.11, range 0.02-0.20 for the active moiety). For umbilical cord plasma, nortriptyline had the highest ratio (mean 2.97, range 0.25-26.43) followed by bupropion (mean 1.14, range 0.3-5.08). For breast milk, the highest ratios were observed for venlafaxine (mean 2.59, range 0.85-4.85), mianserin (mean 2.22, range 0.80-3.64) and escitalopram (mean 2.19, range 1.68-3.00).
Conclusion: We observed considerable variability across antidepressants regarding their ability to enter fetal, newborn and infant fluids. Measuring antidepressant concentrations in a maternal blood sample can provide a reliable estimate of fetal/infant exposure, although further evidence for concentration-dependent effects is required.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7882033 | PMC |
http://dx.doi.org/10.1016/j.pnpbp.2020.110228 | DOI Listing |
BMC Med Educ
January 2025
Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, Bonn, 53127, Germany.
Introduction: The technical development of ultrasound devices based on silicon chips has revolutionized ultrasound examinations, leading to the implementation of these portable handheld devices (PUD) in different medical fields. However, training on these devices is necessary to assure appropriate use and ensure valid results. While training programs for the use of conventional standard ultrasound devices (SUD) have been described, no training program for these handheld devices has been developed thus far.
View Article and Find Full Text PDFFront Pediatr
January 2025
Henan Provincial Institute of Medical Genetics, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, China.
Objective: Our study aimed to collect fetuses with recurrent 1q21.1 deletion or duplication syndrome for systematic clinical phenotype analysis to further delineate the intrauterine phenotype features of the two reciprocal syndromes.
Methods: Prenatal samples, including amniotic fluid and chorionic villus samples, were obtained by amniocentesis and chorionic villus sampling at our center, respectively.
Biol Reprod
January 2025
Department of Animal Science, Texas A&M University, College Station, TX, USA.
The creatine (Cr) biosynthesis pathway buffers ATP in metabolically active tissues. We investigated whether sex of fetus and day of gestation influence Cr in endometrial and conceptus tissues from gilts on Days 60 and Day 90 (n = 6 gilts/day) of gestation. Uterine and conceptus tissues associated with one male and one female fetus from each gilt were analyzed for creatine, mRNAs, and proteins for Cr biosynthesis.
View Article and Find Full Text PDFUltrasound Obstet Gynecol
January 2025
Ultrasound Unit, Helen Schneider Hospital for Women, Rabin Medical Center, Beilinson Hospital, Petach Tikva, Israel.
Objective: Portosystemic shunts in growth-restricted fetuses are more common than previously thought. We aimed to describe fetuses with growth restriction and transient oligohydramnios in which a congenital intrahepatic portosystemic shunt (CIPSS) was noted during follow-up.
Methods: This was a retrospective study of all fetuses diagnosed with growth restriction and transient oligohydramnios during a 5-year period in a large tertiary referral center.
J Magn Reson Imaging
January 2025
Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.
Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.
Study Type: Prospective.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!