Objectives: Selective caries removal (SCR) is recommended over non-selective removal for managing deep carious lesions to avoid pulp exposure and maintain pulp vitality. During SCR, residual carious dentin is left behind and sealed beneath the restoration. The biomechanical effects of such residual lesions on the restored tooth remain unclear and were assessed using finite element modeling (FEM).

Methods: Based on μ-CT images of a healthy permanent human third molar, we developed five finite element models. Generic class I and II cavity restorations were modeled where residual lesions of variable sizes were either left or fully removed on occlusal and proximal surfaces. The cavities were restored with adhesive composite. All 3D-FE models were compared with a model of a healthy, non-treated molar. A vertical load of 100 N was applied onto the occlusal surface.

Results: Regardless of the lesion size, in molars with occlusal lesions higher mean stresses were predicted along the filling-lesion interface than in all other models. The smallest occlusal lesion (Ø = 1 mm) resulted in the highest maximum stresses at the filling-lesion interface with large stress concentrations at the filling walls indicating failure risk. In conclusion, lesion site and extent are influencing parameters affecting the filling-lesion interactions and thus the biomechanical behavior of the tooth after SCR.

Significance: Retaining carious lesions around the pulpal floor affects the deformation and stress states in tooth-filling complexes. The higher stresses observed in molars with occlusal lesions may affect restoration stability and longevity. Suprisingly, more extended occlusal lesions may provide a more favorable tooth performance than less extended ones. In contrast, in molars with proximal lesions the residual lesion had only limited effect on the tooth's biomechanical condition.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2020.11.008DOI Listing

Publication Analysis

Top Keywords

finite element
12
occlusal lesions
12
biomechanical behavior
8
selective caries
8
lesions
8
carious lesions
8
residual lesions
8
molars occlusal
8
higher stresses
8
filling-lesion interface
8

Similar Publications

This study analyzes the influences of surface reactions on the natural convective flow, temperature, and oxygen concentration distributions in vertically placed multilayered cavities. A mathematical model for this problem is formulated with proper boundary conditions. At first, the governing equations are made dimensionless using the variable transformations.

View Article and Find Full Text PDF

In order to systematically study the bending behavior of the connection joints of the disc-buckle type formwork support, the accurate numerical model of the disc-buckle type connection joints was obtained through the experimental on the bending behavior of the connection joints of the disc-buckle type, and the bending moment-rotation curve of the joints was verified. The analysis of the failure mode and stress distribution of the joints reveals the importance of the bending behavior of each component. By establishing an accurate numerical model of the joint, the accuracy of the bending experiment of the joint was verified, and the parametric analysis of the influence factors such as the depth of the wedge insertion the disk-plate, the initial position of the wedge insertion the disk-plate, the thickness of the wedge, material constitutive of the wedge and the thickness of the disk-plate was carried out to grasp the influence of the relevant parameters on the bending behavior of the joint.

View Article and Find Full Text PDF

Objective: Electrical Impedance Tomography (EIT) is a non-invasive technique used for lung imaging. A significant challenge in EIT is reconstructing images of deeper thoracic regions due to the low sensitivity of boundary voltages to internal conductivity variations. The current injection pattern is decisive as it influences the current path, boundary voltages, and their sensitivity to tissue changes.

View Article and Find Full Text PDF

Respiratory diseases represent a significant healthcare burden, as evidenced by the devastating impact of COVID-19. Biophysical models offer the possibility to anticipate system behavior and provide insights into physiological functions, advancements which are comparatively and notably nascent when it comes to pulmonary mechanics research. In this context, an Inverse Finite Element Analysis (IFEA) pipeline is developed to construct the first continuously ventilated three-dimensional structurally representative pulmonary model informed by both organ- and tissue-level breathing experiments from a cadaveric human lung.

View Article and Find Full Text PDF

Radiation efficiency varying equivalent radiated power.

J Acoust Soc Am

January 2025

Grundfos A/S, Bjerringbro, 8550, Denmark.

In this paper, an improved version of the classical equivalent radiated power (ERP) approximation is proposed based on principled physical arguments. A geometry-, frequency-, and vibration pattern-dependent approximation of radiation efficiency is developed and used as a corrective factor for the classical ERP approximation. The proposed method called "radiation efficiency varying equivalent radiated power" (revERP), is shown to greatly improve the accuracy of classical ERP at low Helmholtz numbers, while attaining the accuracy of classical ERP at high Helmholtz numbers.

View Article and Find Full Text PDF