The irradiation facility of the University of Pisa (UNIPI) is a neutron and gamma irradiation facility of the University of Pisa used for calibration purposes and to evaluate detectors and dosemeters for mixed neutron and gamma fields. The facility consists of a fairly large room (5.0 × 7.8 × 2.5 m3) with concrete walls and roof designed to minimise radiation scattering. Sealed neutron and gamma radionuclide sources are stored in the facility for calibration and test purposes. In order to perform accurate response measurements, this study applied a methodology of general validity to assess the neutron and gamma room scatter contributions (albedo) to the fluence and to the ambient dose equivalent rates. The assessment was done for the standard irradiation points of the facility, using detailed Monte Carlo simulations and considering several source-to-wall and source-to-detector distances.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncaa199 | DOI Listing |
Rev Sci Instrum
January 2025
Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium-tritium (DT) fusion plasmas.
View Article and Find Full Text PDFSci Rep
January 2025
Physics Department, Faculty of Science, Fayoum University, Fayoum, Egypt.
For the purpose of this study, four natural rock samples-namely, diorite, granodiorite, tonalite, and granite-are being investigated about their radiation attenuation. The elemental composition of the rocks was obtained through Energy dispersive X-ray spectroscopy (EDX) which examines the microstructural and localized area elemental analyses of the four rock samples. A Monte Carlo simulation (MCNP) was used to determine and evaluate the investigated samples.
View Article and Find Full Text PDFSci Rep
December 2024
Nuclear Engineering Unit, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors.
View Article and Find Full Text PDFNanotechnology
January 2025
Departamento de Física, Química e Matemática, CCTS, UFSCar-campus Sorocaba, Sorocaba, SP 18052-780, Brazil.
Nanomaterials stand out for their exceptional properties and innovative potential, especially in applications that protect against space radiation. They offer an innovative approach to this challenge, demonstrating notable properties of radiation absorption and scattering, as well as flexibility and lightness for the development of protective clothing and equipment. This review details the use of polymeric materials, such as polyimides (PIs), which are efficient at attenuating ultraviolet (UV) radiation and atomic oxygen.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Division of Quantum and Radiation Engineering, Graduate School of Engineering, Osaka Metropolitan University, 1-2 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8570, Japan.
A novel anticoincidence detector is proposed for the measurement of 478 keV gamma radiation for evaluation of boron neutron capture therapy. The Compton continuum around the target photopeak position is effectively suppressed by measuring only the Compton gamma rays scattered at small angles from the primary detector. A numerical evaluation using Monte Carlo simulations estimated an 80% reduction in counts, and the developed prototype detector showed 4% suppression of the Compton continuum of cobalt-60 gamma rays.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!