Non-contact optical detection of ultrasound critically depends on the amount of light collected from the detection surface. Although it can be optimized in multiple ways for an ideal flat polished surface, industrial non-destructive testing and evaluation (NDT&E) usually requires optical detectors to be robust for unpolished material surfaces that are usually rough and curved. Confocal detectors provide the best light collection but must trade off sensitivity with depth of field. Specifically, detection efficiency increases with the numerical aperture (NA) of the detector, but the depth of field drops. Therefore, fast realignment of the detector focal point is critical for in-field applications. Here, we propose an optical distance and angle correction system (DACS) and demonstrate it in a kHz-rate laser-ultrasound inspection system. It incorporates a Sagnac interferometer on receive for the fast scanning of aircraft composites, which minimizes the required initial alignment. We show that DACS performs stably for different composite surfaces while providing ±2° angular and ±2 mm axial automatic correction with a maximum 100 ms realignment time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7766991PMC
http://dx.doi.org/10.3390/s20247266DOI Listing

Publication Analysis

Top Keywords

distance angle
8
angle correction
8
correction system
8
system dacs
8
laser-ultrasound inspection
8
depth field
8
dacs khz
4
khz a-scan
4
a-scan rate
4
rate pump-probe
4

Similar Publications

A reliable and objective method of measuring soft tissue changes in 2D photographs after distraction osteogenesis in individuals with CL/P.

J Plast Surg Hand Surg

January 2025

Department of Clinical Sciences in Malmö, Lund University, Lund, Sweden; Department of Oral and Maxillofacial Surgery, Skåne University Hospital, Malmö, Sweden; Department of Orthodontics, Malmö University, Malmö, Sweden.

Pre- and postoperative photos to assess results are widely used in plastic and reconstructive surgery, for instance, in patients with cleft lip and palate (CL/P). Evaluations are often performed by assessment panels by viewing the photos. However, these are prone to be subjective.

View Article and Find Full Text PDF

Cavitation has been a hot research topic for scholars in various fields because of the intense mechanical, chemical, and thermal effects of bubble collapse. It forms a cluster of bubbles, and the bubbles will affect, interfere with, and couple with each other. To grasp the main factors affecting bubble collapse and the interbubble mechanism, the paper adopts the molecular dynamics simulation combined with the coarse-grained force field to study the collapse process of the double bubble model and takes the dynamic shape change of the bubbles, the local velocity distribution, and the local pressure distribution as the object to summarize the position angle, the shock velocity, and the bubble distance on the collapse law and the primary and secondary influence relationship and then reveals the interbubble mechanism.

View Article and Find Full Text PDF

Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by object's micro-structures. This technique is sensitive to the porous microstructure of lung alveoli and has the potential to detect lung diseases at an early stage. Up to now, a human-scale dark-field CT (DF-CT) prototype has been built for lung imaging.

View Article and Find Full Text PDF

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Purpose: Descemet membrane endothelial keratoplasty (DMEK) has emerged as a novel approach in corneal transplantation over the past two decades. This study aims to identify predisposing risk factors for post-DMEK ocular hypertension (OHT) and develop a preoperative predictive model for post-DMEK OHT.

Methods: Patients who underwent DMEK at Gangnam Severance Hospital between 2017 and 2024 were included in the study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!