Objective: We examined the interobserver reliability of local progressive disease (L-PD) determination using two major radiological response evaluation criteria systems (Response evaluation Criteria in Solid Tumors (RECIST) and the European and American Osteosarcoma Study (EURAMOS)) in patients diagnosed with localized osteosarcoma (OS). Additionally, we describe the outcomes of patients determined to experience L-PD.

Materials And Methods: Forty-seven patients diagnosed with localized OS between 2000 and 2012 at our institution were identified. Paired magnetic resonance imaging of the primary tumor from diagnosis and post-neoadjuvant chemotherapy were blindly assessed by two experienced radiologists and determined L-PD as per RECIST and EURAMOS radiological criteria. Interobserver reliability was measured using the kappa statistic (κ). The Kaplan Meier method and log-rank test was used to assess differences between groups.

Results: Of 47 patients (median age at diagnosis 12.9 years), 16 (34%) had L-PD (by RECIST or EURAMOS radiological definition). There was less agreement between the radiologists using EURAMOS radiological criteria for L-PD (80.9%, κ = 0.48) than with RECIST criteria (97.9%, κ = 0.87). Patients with radiologically defined L-PD had a 5-year progression-free survival (PFS) of 55.6%, compared to a 5 year-PFS of 82.7% in the group of patients without L-PD ( = 31) (Log rank = 0.0185).

Conclusions: The interobserver reliability of L-PD determination is higher using RECIST than EURAMOS. RECIST can be considered for response assessment in OS clinical trials. The presence of L-PD was associated with worse outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767085PMC
http://dx.doi.org/10.3390/jcm9124070DOI Listing

Publication Analysis

Top Keywords

interobserver reliability
12
recist euramos
12
euramos radiological
12
localized osteosarcoma
8
l-pd
8
l-pd determination
8
response evaluation
8
evaluation criteria
8
patients diagnosed
8
diagnosed localized
8

Similar Publications

Stabilised hyaluronic acid gel marker versus surgical clips for tumour bed delineation in breast cancer radiotherapy using MRI-simulation.

Radiother Oncol

January 2025

Department of Radiation Oncology Olivia Newton-John Cancer Wellness & Research Centre Austin Health Victoria Australia; Department of Medical Imaging and Radiation Sciences, Monash University Clayton Victoria Australia; Genesis Care, Ringwood Private Hospital Victoria Australia.

Background And Purpose: Compare breast cancer tumour bed (TB) delineation using stabilised hyaluronic acid (sHA) gel and MRI-simulation versus surgical clips and CT-simulation within same patient cohort.

Materials And Methods: Prospective single arm study of patients undergoing breast conserving surgery. Patients had both clips (≥5) and sHA gel markers inserted to define the TB and underwent MRI and CT simulation scans.

View Article and Find Full Text PDF

This report explores the prevalence of keratoconus in a population-based cohort of adults aged 40 or older according to ten different definitions. All Rotterdam Study participants with reliable Pentacam scans and no prior corneal refractive surgery were cross-sectionally analysed (n = 2660). First, we applied a novel evidence-based definition.

View Article and Find Full Text PDF

The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.

View Article and Find Full Text PDF

Assessment of the interobserver and the intraobserver reproducibility for the detection of renal cortical defects in adults and children using [99mTc]Tc-MAG3.

Q J Nucl Med Mol Imaging

January 2025

Section of Nuclear Medicine and Diagnostic Imaging, International Atomic Energy Agency, Vienna, Austria.

Background: One can assess cortical defects on the early images of [99mTc]Tc-MAG3 renography. We aimed to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to background ratio (KTBR) on reproducibility.

Methods: One hundred adult and 200 pediatric renograms were included.

View Article and Find Full Text PDF

Introduction: Kinematic alignment (KA) in total knee arthroplasty (TKA) is by definition a pure femoral resurfacing procedure aiming to restore the individual prearthritic anatomy. However, when a 2 mm compensation is systematically used on the worn side, the variability in cartilage thickness in the unworn compartment might alter the accuracy of the technique. This study aimed to validate two intraoperative femoral cartilage thickness measurement techniques by comparing them to the photographic method, which measures cartilage thickness through pixel analysis of bone-cut images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!