Objectives: Although commercial iliac branch devices offer a new and valid endovascular approach to treating iliac aneurysm and effectively preserve antegrade flow of the internal iliac artery, their use may not be suited for all types of challenging anatomy, especially isolated common iliac artery aneurysm. Our custom-made iliac bifurcation device has a unique design and excludes both combined and isolated iliac branch aneurysm. This study validated the efficacy and safety of the custom device by comparing clinical outcomes between groups receiving commercial and custom devices.
Methods: Data of consecutive patients receiving iliac bifurcation device implantation for iliac aneurysm with or without concomitant endovascular repair for abdominal aortic aneurysm from January 2010 to May 2019 were reviewed.
Results: Iliac bifurcation device implantation with or without concomitant abdominal aortic aneurysm stent grafting was completed in 46 patients (commercial, n = 35; custom, n = 11). No significant differences were observed regarding postoperative complications, occlusion or endoleak. Comparisons of primary (80.8% vs 85.7%, P = 0.88) and secondary (86.5% vs 85.7%, P = 0.85) patency and freedom from reintervention (88.2% vs 100%, P = 0.33), all-cause mortality (78.6% vs 100%, P = 0.25) and aneurysm-related mortality (100% vs 100%, P = 1.00) also indicated no differences at a 5-year surveillance point. Furthermore, the iliac aneurysms of the groups displayed similar shrinkage 1 year after procedures.
Conclusions: For iliac aneurysm, the novel custom-made iliac bifurcation device is an adaptable design not inferior to commercial devices with regard to postoperative complications, bridge occlusion, endoleak and short-term aneurysm remodelling. It provides an alternative for treatment, particularly when certain anatomic challenges are present.
Clinical Trial Registration: 2018-07-050BC, 2017-01-023ACF.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8972831 | PMC |
http://dx.doi.org/10.1093/icvts/ivaa229 | DOI Listing |
Int J Surg Case Rep
January 2025
Department of Vascular Surgery, Inselspital, University Hospital, University of Bern, 3010 Bern, Switzerland.
Introduction And Importance: Internal iliac artery aneurysms repair represents a life-threatening condition due to their anatomical position and the risk of rupture. Iliac branch devices are strongly recommended for anatomically suitable patients, but limited alternatives exist when their use is unsuitable. The use of custom-made fenestrated endografts is well documented in other aortic territories, however, their application for the treatment of internal iliac artery aneurysm remains limited.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Sathyamoorthy Laboratory, Department of Medicine, Burnett School of Medicine at TCU, Fort Worth, TX 76104, USA.
After reporting the first known clinical case associating compound heterozygous single-nucleotide variants in Exon 2 of to aortic aneurysmal and iliac dissection, we began prospective surveillance in our vascular genetic practice for similar cases. Herein, we present nine (9) subjects from a total cohort of 135 with arterial aneurysms or dissections who revealed single-nucleotide variants in with no other alterations in a panel of 35 genes associated with aneurysmal and dissection disorders. Five out of nine (5/9) single-nucleotide variants were in Exon 1, and four out of nine (4/9) mutations were in Exon 2, both of which are principal coding exons for this gene.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
February 2025
Department of Vascular and Endovascular Surgery, Beth Israel Deaconess Hospital, Boston, MA.
J Nippon Med Sch
January 2025
Department of Radiology, Nippon Medical School.
As a blood flow control technique for embolization using glue (n-butyl cyanoacrylate; NBCA) for peripheral artery aneurysm/pseudoaneurysm, we placed a vascular plug or coils at the proximal inflow vessel before glue injection. We describe this maneuver, which we call the glue in lockdown technique. Four peripheral aneurysms-two pulmonary artery pseudoaneurysms, one pancreaticoduodenal arcade pseudoaneurysm, and one internal iliac artery aneurysm-deemed unsuitable for conventional embolization because of abnormal blood flow, coagulopathy, or anatomical complexity were embolized with our technique.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000, P. R. China.
The absence or dysplasia of the iliac artery(IA) is an exceedingly rare condition, with limited cases documented in the literature. In this report, we present a case of hypoplasia of the right external iliac artery (EIA) in a 69-year-old male patient. The patient presented with right lower abdominal pain attributed to an aneurysm of the right internal iliac artery (IIA), yet notably, there was no evidence of lower limb ischemia at the time of consultation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!