Background: It is common practice to observe patients during an overnight stay (ONS) following a catheter ablation procedure for the treatment of atrial fibrillation (AF).

Objectives: To investigate the safety and economic impact of a same-day discharge (SDD) protocol after cryoballoon ablation for treatment of AF in high-volume, geographically diverse US hospitals.

Methods: We retrospectively reviewed 2374 consecutive patients (1119 SDD and 1180 ONS) who underwent cryoballoon ablation for AF at three US centers. Baseline characteristics, acute procedure-related complications, and longer-term evaluations of safety were recorded during routine clinical follow-up. The mean cost of an ONS was used in a one-way sensitivity analysis to evaluate yearly cost savings as a function of the percentage of SDD cases per year.

Results: The SDD and ONS cohorts were predominately male (69% vs. 67%; p = .3), but SDD patients were younger (64 ± 11 vs. 66 ± 10; p < .0001) with lower body mass index (30 ± 6 vs. 31 ± 61; p < .0001) and CHA DS -VASc scores (1.4 ± 1.0 vs. 2.2 ± 1.4; p < .0002). There was no difference between SDD and ONS in the 30-day total complication rate (n = 15 [1.26%] versus n = 24 [2.03%]; p = .136, respectively). The most common complication was hematoma in both the SDD (n = 8; 0.67%) and ONS (n = 11; 0.93%) cohorts. Sensitivity analysis demonstrated that when 50% of every 100 patients treated were discharged the same day, hospital cost savings ranged from $45 825 to $83 813 per year across US hospitals.

Conclusions: SDD following cryoballoon ablation for AF appears to be safe and is associated with cost savings across different US hospitals.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.14843DOI Listing

Publication Analysis

Top Keywords

cryoballoon ablation
12
same-day discharge
8
atrial fibrillation
8
sdd
5
discharge cryoballoon
4
ablation
4
ablation atrial
4
fibrillation multicenter
4
multicenter experience
4
experience background
4

Similar Publications

Introduction: A hybrid approach with very high-power short-duration (vHPSD) posteriorly and ablation-index guided HPSD (50 W) anteriorly seems to be an optimal balance between efficiency and effectiveness for point-by-point pulmonary vein isolation (PVI). The aim of the current study is to compare vHPSD/HPSD ablation to cryoballoon ablation (CBA) in patients with symptomatic atrial fibrillation (AF).

Methods And Results: In this retrospective single-center study, we identified 110 consecutive patients who underwent their first PVI with either vHPSD/HPSD (n = 54) or CBA (n = 56).

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

Pulsed field ablation (PFA) is a novel nonthermal ablation technique for the treatment of atrial fibrillation (AF) patients, with safety comparable to traditional catheter ablation surgery. The present study aims to evaluate and compare the procedural efficiency and safety profiles of PFA and cryoballoon ablation (CBA) in the management of AF. We performed a systematic search across PubMed, the Cochrane Library, and Embase databases, encompassing the literature up to February 2024, to inform our systematic review and meta-analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!